Parameter
Description
Selection / User entry
Factory setting
Densityйunit
Selectйdensityйunit.
Result
Theйselectedйunitйappliesйfor:
• Output
• Simulationйprocessйvariable
• Densityйadjustmentйсinй
Expert
йmenu)
Unitйchooseйlist
Country-specific:
• kg/l
• lb/ft³
Fixedйdensity
Enterйfixedйvalueйforйmediumйdensity.
0.01йtoй15
й
000йkg/m³
1
й
000йkg/m³
Valueйperйpulse
Enterйmeasuredйvalueйatйwhichйaйpulseйis
output.
Signedйfloating-pointйnumber
0
Pulseйwidth
Defineйtimeйwidthйofйtheйoutputйpulse.
0.05йtoй2
й
000йms
100йms
Failureйmode
Defineйoutputйbehaviorйinйalarmйcondition.
• Actualйvalue
• Noйpulses
Noйpulses
Invertйoutputйsignal
Invertйtheйoutputйsignal.
• No
• Yes
No
Frequency output
Navigation
"Setup"йmenuй йPulse/frequency/switchйoutputй1йtoй2