Systemйintegration
ProlineйPromagйDй400йHART
66
Hauser
Theйassignmentйofйtheйmeasuredйvariablesйtoйtheйdynamicйvariablesйcanйbeйmodifiedйand
assignedйasйdesiredйviaйlocalйoperationйandйtheйoperatingйtoolйusingйtheйfollowing
parameters:
• Expertй йCommunicationй йHARTйoutputй йOutputй йAssignйPV
• Expertй йCommunicationй йHARTйoutputй йOutputй йAssignйSV
• Expertй йCommunicationй йHARTйoutputй йOutputй йAssignйTV
• Expertй йCommunicationй йHARTйoutputй йOutputй йAssignйQV
й
Theйfollowingйmeasuredйvariablesйcanйbeйassignedйtoйtheйdynamicйvariables:
Measured variables for PV (primary dynamic variable)
• Off
• Volumeйflow
• Massйflow
• Flowйvelocity
• Electronicйtemperature
Measured variables for SV, TV, QV (secondary, tertiary and quaternary dynamic
variable)
• Volumeйflow
• Massйflow
• Electronicйtemperature
• Totalizerй1
• Totalizerй2
• Totalizerй3
Device variables
Theйdeviceйvariablesйareйpermanentlyйassigned.йAйmaximumйofй8йdeviceйvariablesйcanйbe
transmitted:
• 0й=йvolumeйflow
• 1й=йMassйflow
• 2й=йconductivity
• 3й=йflowйvelocity
• 4й=йelectronicйtemperature
• 5й=йtotalizerй1
• 6й=йtotalizerй2
• 7й=йtotalizerй3
9.3
Other settings
9.3.1
Burst mode functionality in accordance with HART 7
Specification
Navigation
"Expert"йmenuй йCommunicationй йHARTйoutputй йBurstйconfigurationй йBurst
configurationй1йtoй3
Structure of the submenu
Burst configuration 1 to 3
Burstйmode
Burstйcommand
Burstйvariableй0
…