Systemйintegration
ProlineйPromagйDй400йHART
68
Hauser
Parameter
Description
Selection / User entry
Factory setting
Burstйtriggerйmode
Useйthisйfunctionйtoйselectйtheйeventйthat
triggersйburstйmessageйX.
•
Continuous
йoption:
Theйmessageйisйtriggeredйinйaйtime-
controlledйmanner,йatйleastйobservingйthe
timeйintervalйdefinedйinйtheй
Burst min
period
йparameter.
•
Window
йoption:
Theйmessageйisйtriggeredйifйtheйspecified
measuredйvalueйhasйchangedйbyйtheйvalue
inйtheй
Burst trigger level
йparameter.
•
Rising
йoption:
Theйmessageйisйtriggeredйifйtheйspecified
measuredйvalueйexceedsйtheйvalueйinйthe
Burst trigger level
йparameter.
•
Falling
йoption:
Theйmessageйisйtriggeredйifйtheйspecified
measuredйvalueйdropsйbelowйtheйvalueйin
theй
Burst trigger level
йparameter.
•
On change
йoption:
Theйmessageйisйtriggeredйifйtheйmeasured
valueйchanges.
• Continuous
• Window
• Rising
• Falling
• Onйchange
Continuous
Burstйtriggerйlevel
Forйenteringйtheйburstйtriggerйvalue.
Togetherйwithйtheйoptionйselectedйinйthe
Burst trigger mode
йparameterйtheйburst
triggerйvalueйdeterminesйtheйtimeйofйburst
messageйX.
Positiveйfloating-pointйnumber 2.0E-38
Min.йupdateйperiod
Useйthisйfunctionйtoйenterйtheйminimumйtime
spanйbetweenйtwoйburstйcommandsйofйburst
messageйX.
Positiveйinteger
1
й
000йms
Max.йupdateйperiod
Useйthisйfunctionйtoйenterйtheйmaximum
timeйspanйbetweenйtwoйburstйcommandsйof
burstйmessageйX.
Positiveйinteger
2
й
000йms