Cerabar PMP71B HART
Installation
Hauser
23
Item
T
a
T
p
C
67 °C (153 °F)
400 °C (752 °F)
85 °C (185 °F)
200 °C (392 °F)
–50 °C (–58 °F)
70 °C (158 °F)
–35 °C (–31 °F)
–70 °C (–94 °F)
1)
Maximum ambient temperature at transmitter
2)
Maximum process temperature
3)
Process temperature: max. +400 °C (+752 °F), depending on the diaphragm seal fill fluid used
5.2.8
Seal for flange mounting
NOTICE
Seal pressing against the process isolating diaphragm!
Incorrect measurement results!
‣
Ensure that the seal is not touching the process isolating diaphragm.
1
2
A0017743
1
Process isolating diaphragm
2
Seal
5.2.9
Mounting bracket for measuring device or separate housing
The measuring device or separate housing can be mounted on walls or pipes (for pipes
with a diameter ranging from 1 ¼" to 2") with the mounting bracket.
122 (4.8)
52 (2.05)
86 (3.39)
70 (2.76)
140 (5.51)
158 (6.22)
175 (6.89)
ø6 (0.24)
ø42...60 (1.65...2.36)
A0028493
Unit of measurement mm (in)
Содержание Hart Cerabar PMP71B
Страница 4: ...Table of contents Cerabar PMP71B HART 4 Endress Hauser 15 2 Environment 71 15 3 Process 75 Index 82...
Страница 74: ...Technical data Cerabar PMP71B HART 74 Endress Hauser For more details refer to the EU Declaration of Conformity...
Страница 83: ......
Страница 84: ...www addresses endress com 71521418 71521418...