![Emerson Unidrive M100 Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/emerson/unidrive-m100/unidrive-m100_control-user-manual_2400832054.webp)
54
Unidrive M100 / M101 Control User Guide
Issue Number: 1
* Keypad mode for the
Unidrive M101
.
Parameter
Range
(
Ú
)
Default
(
Ö
)
Type
OL
OL
01.001
Reference Selected
VM_SPEED_FREQ_REF Hz
RO
Num
ND
NC
PT
01.002
Pre-skip Filter Reference
VM_SPEED_FREQ_REF Hz
RO
Num
ND
NC
PT
01.003
Pre-ramp Reference
VM_SPEED_FREQ_REF Hz
RO
Num
ND
NC
PT
01.004
Reference Offset
VM_SPEED_FREQ_REF Hz
0.00 Hz
RW
Num
US
01.005
Jog Reference
0.00 to 300.00 Hz
1.50 Hz
RW
Num
US
01.006
Maximum Reference Clamp
VM_POSITIVE_REF_CLAMP Hz
50 Hz: 50.00 Hz
60 Hz: 60.00 Hz
RW
Num
US
01.007
Minimum Reference Clamp
VM_NEGATIVE_REF_CLAMP1 Hz
0.00 Hz
RW
Num
US
01.008
Negative Reference Clamp
Enable
Off (0) or On (1)
Off (0)
RW
Bit
US
01.009
Reference Offset Select
0 to 2
0
RW
Num
US
01.010
Bipolar Reference Enable
Off (0) or On (1)
Off (0)
RW
Bit
US
01.011
Reference On
Off (0) or On (1)
RO
Bit
ND
NC
PT
01.012
Reverse Select
Off (0) or On (1)
RO
Bit
ND
NC
PT
01.013
Jog Select
Off (0) or On (1)
RO
Bit
ND
NC
PT
01.014
Reference Selector
A1.A2 (0), A1.Pr (1), rES (2), PrESEt (3),
PAd (4), rES (5), PAd.rEF (6)
A1.A2 (0)
*
RW
Txt
US
01.015
Preset Selector
0 to 9
0
RW
Num
US
01.016
Preset Selector Timer
0 to 400.0 s
10.0s
RW
Num
US
01.017
Keypad Control Mode
Reference
VM_SPEED_FREQ_USER_REFS Hz
RO
Num
NC
PT
PS
01.021
Preset Reference 1
VM_SPEED_FREQ_REF Hz
0.00 Hz
RW
Num
US
01.022
Preset Reference 2
VM_SPEED_FREQ_REF Hz
0.00 Hz
RW
Num
US
01.023
Preset Reference 3
VM_SPEED_FREQ_REF Hz
0.00 Hz
RW
Num
US
01.024
Preset Reference 4
VM_SPEED_FREQ_REF Hz
0.00 Hz
RW
Num
US
01.025
Preset Reference 5
VM_SPEED_FREQ_REF Hz
0.00 Hz
RW
Num
US
01.026
Preset Reference 6
VM_SPEED_FREQ_REF Hz
0.00 Hz
RW
Num
US
01.027
Preset Reference 7
VM_SPEED_FREQ_REF Hz
0.00 Hz
RW
Num
US
01.028
Preset Reference 8
VM_SPEED_FREQ_REF Hz
0.00 Hz
RW
Num
US
01.029
Skip Reference 1
0.00 to 550.00 Hz
0.00 Hz
RW
Num
US
01.030
Skip Reference Band 1
0.00 to 25.00 Hz
0.50 Hz
RW
Num
US
01.031
Skip Reference 2
0.00 to 550.00 Hz
0.00 Hz
RW
Num
US
01.032
Skip Reference Band 2
0.00 to 25.00 Hz
0.50 Hz
RW
Num
US
01.033
Skip Reference 3
0.00 to 550.00 Hz
0.00 Hz
RW
Num
US
01.034
Skip Reference Band 3
0.00 to 25.00 Hz
0.50 Hz
RW
Num
US
01.035
Reference In Rejection Zone
Off (0) or On (1)
RO
Bit
ND
NC
PT
01.036
Analog Reference 1
VM_SPEED_FREQ_USER_REFS Hz
0.00 Hz
RO
Num
NC
01.038
Percentage Trim
±100.00 %
0.00 %
RW
Num
NC
01.041
Reference Select Flag 1
Off (0) or On (1)
Off (0)
RW
Bit
NC
01.042
Reference Select Flag 2
Off (0) or On (1)
Off (0)
RW
Bit
NC
01.043
Reference Select Flag 3
Off (0) or On (1)
Off (0)
RW
Bit
NC
01.045
Preset Select Flag 1
Off (0) or On (1)
Off (0)
RW
Bit
NC
01.046
Preset Select Flag 2
Off (0) or On (1)
Off (0)
RW
Bit
NC
01.047
Preset Select Flag 3
Off (0) or On (1)
Off (0)
RW
Bit
NC
01.048
Preset Selector Timer Reset
Off (0) or On (1)
Off (0)
RW
Bit
NC
01.049
Reference Selected Indicator
1 to 6
RO
Num
ND
NC
PT
01.050
Preset Selected Indicator
1 to 8
RO
Num
ND
NC
PT
01.051
Power-up Keypad Control Mode
Reference
rESEt (0), LASt (1), PrESEt (2)
rESEt (0)
RW
Txt
US
01.057
Force Reference Direction
NonE (0), For (1), rEv (2)
NonE (0)
RW
Txt
01.069
Reference in rpm
VM_SPEED_FREQ_REF rpm
RO
Num
ND
NC
PT
01.070
Clamped Reference
VM_SPEED_FREQ_REF Hz
RO
Num
ND
NC
PT
01.071
Alternative Reference
VM_SPEED_FREQ_REF Hz
0.00 Hz
RW
Num
NC
PT
01.072
Alternative Reference Enable
Off (0) or On (1)
RO
Bit
ND
NC
PT
RW
Read / Write
RO
Read only
Num Number parameter
Bit
Bit parameter
Txt Text string
Bin
Binary parameter
FI
Filtered
ND
No default value
NC
Not copied
PT
Protected parameter
RA
Rating dependent
US User save
PS
Power-down save
DE Destination
Date
Date parameter
Time Time parameter
Содержание Unidrive M100