Unidrive M100 / M101 Control User Guide
29
Issue Number: 1
Figure 6-6 Pr 00.005 = AV.Pr (50 Hz)
Figure 6-7 Pr 00.005 = AV.Pr (60 Hz)
Figure 6-8 Pr 00.005 = AI.Pr (50 Hz)
Figure 6-9 Pr 00.005 = AI.Pr (60 Hz)
1
2
4
9
0 V
10k
Voltage speed
reference input (AI 1)
Reference select
Reference select
10
11
12
13
Drive enable
Run forward
+ 10 V output
+ 24 V output
Terminal 10 Terminal 13 Reference selected
0
0
Analog reference 1*
0
1
Preset speed 2*
1
0
Preset speed 3*
1
1
Preset speed 4*
1
2
4
9
0 V
10k
Voltage speed
reference input (AI 1)
Reference select
Reference select
10
11
12
13
Not stop
Run
+ 10 V output
+ 24 V output
Terminal 10 Terminal 13 Reference selected
0
0
Analog reference 1*
0
1
Preset speed 2*
1
0
Preset speed 3*
1
1
Preset speed 4*
1
2
4
9
0 V
Current speed
reference input (AI 1)
Reference select
Reference select
10
11
12
13
Drive enable
Run forward
+ 10 V output
+ 24 V output
Current speed
reference input
Terminal 10 Terminal 13 Reference selected
0
0
Analog reference 1*
0
1
Preset speed 2*
1
0
Preset speed 3*
1
1
Preset speed 4*
1
2
4
9
0 V
Current speed
reference input (AI 1)
Reference select
Reference select
10
11
12
13
Not stop
Run
+ 10 V output
+ 24 V output
Current speed
reference input
Terminal 10 Terminal 13 Reference selected
0
0
Analog reference 1*
0
1
Preset speed 2*
1
0
Preset speed 3*
1
1
Preset speed 4*