Unidrive M100 / M101 Control User Guide
31
Issue Number: 1
Figure 6-14 Pr 00.005 = torquE (50 Hz)
Figure 6-15 Pr 00.005 = torquE (60 Hz)
1
2
4
9
0 V
10k
Torque reference
input (AI 1)
Digital output
(zero frequency)
Torque mode select
10
11
12
13
Drive enable
Run forward
+ 10 V output
+ 24 V output
When torque mode is selected and the drive is connected to
an unloaded motor, the motor speed may increase rapidly to
the maximum speed (Pr
00.002
+10 %)
WARNING
1
2
4
9
0 V
10k
Torque reference
input (AI 1)
Digital output
(zero frequency)
Torque mode
select
10
11
12
13
Not stop
Run
+ 10 V output
+ 24 V output
When torque mode is selected and the drive is connected to
an unloaded motor, the motor speed may increase rapidly to
the maximum speed (Pr
00.002
+10 %)
WARNING
Содержание Unidrive M100