Unidrive M100 / M101 Control User Guide
73
Issue Number: 1
Parameter
Range
(
Ú
)
Default
(
Ö
)
Type
OL
OL
08.001
Digital I/O 1 State (T10)
Off (0) or On (1)
RO
Bit
ND NC PT
08.002
Digital Input 2 State(T11)
Off (0) or On (1)
RO
Bit
ND NC PT
08.003
Digital Input 3 State (T12)
Off (0) or On (1)
RO
Bit
ND NC PT
08.004
Digital Input 4 State (T13)
Off (0) or On (1)
RO
Bit
ND NC PT
08.008
Relay 1 Output State
Off (0) or On (1)
RO
Bit
ND NC PT
08.011
Digital I/O 1 Invert (T10)
Not.Inv (0), InvErt (1)
Not.Inv (0)
RW
Txt
US
08.012
Digital Input 2 Invert (T11)
Not.Inv (0), InvErt (1)
Not.Inv (0)
RW
Txt
US
08.013
Digital Input 3 Invert (T12)
Not.Inv (0), InvErt (1)
Not.Inv (0)
RW
Txt
US
08.014
Digital Input 4 Invert (T13)
Not.Inv (0), InvErt (1)
Not.Inv (0)
RW
Txt
US
08.018
Relay 1 Invert
Not.Inv (0), InvErt (1)
Not.Inv (0)
RW
Txt
US
08.020
Digital I/O Read Word
0 to 2048
RO Num ND NC PT
08.021
Digital IO1 Source / Destination A (T10)
0.000 to 30.999
10.003
RW Num DE
PT US
08.022
Digital Input 2 Destination A (T11)
0.000 to 30.999
50 Hz: 6.038
60 Hz: 6.039
RW Num DE
PT US
08.023
Digital Input 03 Destination A (T12)
0.000 to 30.999
50 Hz: 6.030
60 Hz: 6.034
RW Num DE
PT US
08.024
Digital Input 04 Destination A (T13)
0.000 to 30.999
50 Hz: 6.032
60 Hz: 6.031
RW Num DE
PT US
08.028
Relay 1 Output Source A
0.000 to 30.999
10.001
RW Num
PT US
08.031
Digital I/O 01 Output Mode (T10)
InPut (0), OutPut (1),
Fr (2), PuLSE (3)
OutPut (1)
RW
Txt
US
08.043
24 V Supply Input State
Off (0) or On (1)
RO
Bit
ND NC PT
08.053
24 V Supply Invert
Not.Inv (0), InvErt (1)
Not.Inv (0)
RW
Txt
US
08.063
24 V Supply Input Destination
0.000 to 30.999
0.000
RW Num DE
PT US
08.081
DI1 Control (T10)
0 to 21
0
RW Num
US
08.082
DI2 Control (T11)
0 to 21
0
RW Num
US
08.083
DI3 Control (T12)
0 to 21
0
RW Num
US
08.084
DI4 Control (T13)
0 to 21
0
RW Num
US
08.091
DO1 Control
0 to 20
0
RW Num
US
08.098
Relay 1 Control
0 to 20
0
RW Num
US
08.121
DI/O 01 Source / Destination B (T10)
0.000 to 30.999
RO Num DE
PT US
08.122
Digital Input 2 Destination B (T11)
0.000 to 30.999
RO Num DE
PT US
08.123
DI 03 Destination B (T12)
0.000 to 30.999
RO Num DE
PT US
08.124
DI 04 Destination B (T13)
0.000 to 30.999
RO Num DE
PT US
08.128
Relay 01 Source B
0.000 to 30.999
0.000
RW Num
PT US
RW
Read / Write
RO
Read only
Num Number parameter
Bit
Bit parameter
Txt Text string
Bin
Binary parameter
FI
Filtered
ND
No default value
NC
Not copied
PT
Protected parameter
RA
Rating dependent
US User save
PS
Power-down save
DE Destination
Date
Date parameter
Time Time parameter