62
Unidrive M100 / M101 Control User Guide
Issue Number: 1
Parameter
Range
(
Ú
)
Default
(
Ö
)
Type
OL
OL
04.001
Current Magnitude
VM_DRIVE_CURRENT A
RO Num ND NC PT
FI
04.002
Torque Producing Current
VM_DRIVE_CURRENT A
RO Num ND NC PT
FI
04.003
Final Torque Reference
VM_TORQUE_CURRENT %
RO Num ND NC PT
FI
04.004
Final Current Reference
VM_TORQUE_CURRENT %
RO Num ND NC PT
FI
04.005
Motoring Current Limit
0.0 to
VM_MOTOR1_CURRENT_LIMIT %
165.0 %
RW Num
RA
US
04.006
Regenerating Current Limit
0.0 to
VM_MOTOR1_CURRENT_LIMIT %
165.0 %
RW Num
RA US
04.007
Symmetrical Current Limit
0.0 to
VM_MOTOR1_CURRENT_LIMIT %
165.0 %
RW Num
RA
US
04.008
Torque Reference
VM_USER_CURRENT %
0.0 %
RW Num
US
04.011
Torque Mode Selector
0 to 1
0
RW Num
US
04.013
Current Controller Kp Gain
0.00 to 4000.00
20.00
RW Num
US
04.014
Current Controller Ki Gain
0.000 to 600.000
40.000
RW Num
US
04.015
Motor Thermal Time Constant 1
1 to 3000 s
179 s
RW Num
US
04.016
Thermal Protection Mode
0 (0) to 3 (3)
0 (0)
RW
Bin
US
04.017
Magnetising Current
VM_DRIVE_CURRENT A
RO Num ND NC PT
FI
04.018
Final Current Limit
VM_TORQUE_CURRENT %
RO Num ND NC PT
04.019
Motor Protection Accumulator
0.0 to 100.0 %
RO Num ND NC PT
PS
04.020
Percentage Load
VM_USER_CURRENT %
RO Num ND NC PT
FI
04.024
User Current Maximum Scaling
0.0 to VM_TORQUE_CURRENT_
UNIPOLAR %
165.0 %
RW Num
RA
US
04.025
Low Frequency Thermal
Protection Mode
0 to 1
0
RW Num
US
04.026
Percentage Torque
VM_USER_CURRENT %
RO Num ND NC PT
FI
04.036
Motor Protection Accumulator
Power-up Value
Pr.dn (0), 0 (1)
Pr.dn (0)
RW
Txt
US
04.041
User Over Current Trip Level
0 to 100 %
100 %
RW Num
RA
US
RW
Read / Write
RO
Read only
Num Number parameter
Bit
Bit parameter
Txt Text string
Bin
Binary parameter
FI
Filtered
ND
No default value
NC
Not copied
PT
Protected parameter
RA
Rating dependent
US User save
PS
Power-down save
DE Destination
Date
Date parameter
Time Time parameter
Содержание Unidrive M100