5.10.1
Verify alarm output
To verify the alarm output, use Rosemount Radar Master to simulate a device failure:
Procedure
1. Establish HART communication with the transmitter through Rosemount Radar
Master.
2. Select
Tools
→
Simulation Mode
.
3. Select
Enable Device Failure Alarm (simulated)
.
4. Select
Start
.
5. Disconnect HART modem.
6. Verify that the configured alarm output is available in the Modbus host.
7. Use Rosemount Radar Master to turn off simulation mode.
5.10.2
Use status information to evaluate measurement
validity
The transmitter updates status information about the current measurement, and this
status information is available as a bitfield register through Modbus communication.
By monitoring the status information it is possible to determine if the current
measurement output value is valid. See
Common Modbus host configuration
for details
about the individual status bits.
5.10.3
Use Heartbeat to detect errors
By reading and evaluating the Heartbeat value from the device, it is possible to verify that
the communication link between the transmitter, HMC, RTU and even the control system
communicating with the RTU is working.
Assign Heartbeat to one of the transmitter variables (SV, TV, or QV). Heartbeat is
increased by one for each measurement cycle in the device (until it eventually starts over
at zero again).
In case this value is not updated, it means that the communication link is broken.
Reference Manual
Configuration
00809-0100-4530
April 2019
Reference Manual
155
Содержание Rosemount 5300 Series
Страница 1: ...Reference Manual 00809 0100 4530 Rev FA April 2019 Rosemount 5300 Level Transmitter Guided Wave Radar ...
Страница 26: ...Transmitter overview Reference Manual April 2019 00809 0100 4530 26 Rosemount 5300 Level Transmitter ...
Страница 112: ...Electrical installation Reference Manual April 2019 00809 0100 4530 112 Rosemount 5300 Level Transmitter ...
Страница 158: ...Configuration Reference Manual April 2019 00809 0100 4530 158 Rosemount 5300 Level Transmitter ...
Страница 168: ...Operation Reference Manual April 2019 00809 0100 4530 168 Rosemount 5300 Level Transmitter ...
Страница 244: ...Service and troubleshooting Reference Manual April 2019 00809 0100 4530 244 Rosemount 5300 Level Transmitter ...
Страница 380: ...Product certifications Reference Manual April 2019 00809 0100 4530 380 Rosemount 5300 Level Transmitter ...
Страница 396: ...Configuration parameters Reference Manual April 2019 00809 0100 4530 396 Rosemount 5300 Level Transmitter ...
Страница 487: ...Reference Manual 00809 0100 4530 April 2019 Reference Manual 487 ...