Parameter
08.018
24V Supply Output Invert
Short description
Set to invert 24V Supply Output
Mode
Open
‑
Loop
Minimum
0
Maximum
1
Default
1
Units
Type
8 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW, TE
Value
Text
0
Not Invert
1
Invert
See
Digital I/O 01 Invert
(08.011).
Parameter
08.020
Digital I/O Read Word
Short description
Displays the states for digital I/O 1 to 8
Mode
Open
‑
Loop
Minimum
0
Maximum
511
Default
Units
Type
16 Bit Volatile
Update Rate
Background write
Display Format
Standard
Decimal Places
0
Coding
RO, ND, NC, PT
Digital I/O Read Word
(08.020) reflects the state of digital input/output 1 to STO input 1 as given below. Each bit matches the value of the state
parameter for the respective digital input or output.
Digital I/O Read Word
(08.020) bit
Digital I/O
0
Digital I/O 1
1
Digital I/O 2
2
Digital I/O 3
3
Digital Input 4
4
Digital Input 5
5
Digital Input 6
6
Relay
7
24V Output
8
STO Input 1
Parameter
08.021
Digital I/O 01 Source/Destination
Short description
Defines the source or destination parameter for Digital I/O 1
Mode
Open
‑
Loop
Minimum
0.000
Maximum
59.999
Default
10.002
Units
Type
16 Bit User Save
Update Rate
Drive Reset Read
Display Format
Standard
Decimal Places
3
Coding
RW, DE, PT, BU
The Digital I/O Source/Destination parameters provide the routing for the source and/or destination for the digital I/O.
Parameter
08.022
Digital I/O 02 Source/Destination
Short description
Defines the source or destination parameter for Digital I/O 2
Mode
Open
‑
Loop
Minimum
0.000
Maximum
59.999
Default
10.033
Units
Type
16 Bit User Save
Update Rate
Drive Reset Read
Display Format
Standard
Decimal Places
3
Coding
RW, DE, PT, BU
See
Digital I/O 01 Source/Destination
(08.021).
Parameter
08.023
Digital I/O 03 Source/Destination
Short description
Defines the source or destination parameter for Digital I/O 3
Mode
Open
‑
Loop
Minimum
0.000
Maximum
59.999
Default
6.030
Units
Type
16 Bit User Save
Update Rate
Drive Reset Read
Display Format
Standard
Decimal Places
3
Coding
RW, DE, PT, BU
132
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00
Содержание Powerdrive F300
Страница 1: ...Parameter Reference Guide Powerdrive F300 Open Loop Mode Issue 01 15 00 ...
Страница 20: ...Menu 1 Frequency References Mode Open Loop 20 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Страница 21: ...Powerdrive F300 Parameter Reference Guide Issue 01 15 00 21 ...
Страница 36: ...Menu 2 Frequency Ramps Mode Open Loop 36 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Страница 108: ...Menu 7 Single Line Descriptions Analog I O Mode Open Loop 108 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Страница 112: ...112 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Страница 144: ...144 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Страница 168: ...Menu 10 Status and Trips Mode Open Loop 168 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...
Страница 231: ...Powerdrive F300 Parameter Reference Guide Issue 01 15 00 231 ...
Страница 232: ...232 Powerdrive F300 Parameter Reference Guide Issue 01 15 00 ...