72
Section 14: Fuses
Fuses
User Instructions
MAN-02-04-60-0351-EN Rev. 3
Febraury 2019
Section 15: Lubricant Recommendation
and Requirements
15.1
Main Body: -25 to +60C
Operating oil: DIN 51 517-CLP-HC
i.e. fully synthetic high-performance gear oils based on poly-alpha-olefins (PAO)
Viscosity class:
320 ISO VG
Pourpoint:
< -39C (according DIN ISO 3016)
Lubricant requirement CM03:
200. . . 250 ml
Lubricant requirement CM06:
400. . . 450 ml
15.2
Main Body: -40 to +60C
Operating oil: DIN 51 517-CLP-HC
i.e. fully synthetic high-performance gear oils based on poly-alpha-olefins (PAO)
Viscosity class:
68 ISO VG
Pourpoint:
< -54C (according DIN ISO 3016)
Lubricant requirement CM03:
200. . . 250 ml
Lubricant requirement CM06:
400. . . 450 ml
15.3
Output Type A and Spindle Drives
(Linear Actuators) -40 to +60C
Grease DIN 51825-K(P) R -40
i.e. water repellent complex grease on Al-soap base with high resistance to acids and alkalis
Penetration 0.1 mm:
to 265
Dropping point:
about 260C
NLGI
No.:
1
acid-free, little or not water-reactive
15.4
Basic Lubricant Service Interval
CAUTION: CONSIDER REDUCTION FACTORS
The service interval for RTS CM Compact Series actuators is ten years from the shipping
date, Emerson. However, the functionality and service life of the lubricants depends on the
operating conditions. Reduction factors have to be taken into consideration if applicable.