English
oil then dry the filter again in an absorbent cloth in order to remove the excess oil.
• Clean the cartridge by tapping it gently against a flat surface.
• Refit the cartridge (with the UP mark showing upwards) and screw down.
• Refit the pre-cleaner to the cartridge.
• Refit the cover and secure the cover using the hold-down clamps.
11.3.6 Changing the air filter
These actions are almost identical to cleaning the air cleaner (see Chapter 11.3.5). The only differ-
ence here is that the cartridge is replaced.
New air cleaners of the correct type are available from your ELIET Dealer or from an authorized
Honda or Subaru service centre.
11.3.7 Adding additional battery acid
Warning :
Battery acid is corrosive and therefore dangerous. Wear safety glasses and
protective garment and work in a well-ventilated area.
• Switch off the engine.
• Check to be sure electrolyte level is between the minimum and maximum marks. Inspect the
six compartments for correct level by looking through the transparent battery case.
• If the level is not correct, unscrew the caps from the battery.
• Use only distilled water to top up to the correct electrolyte level.
• Refit the caps to the battery.
Caution :
Do not inhale vapours from the battery acid.
During this maintenance, do not rub your eyes with your hands.
Should battery acid splatter into the eyes or onto the face, rinse the affected
area immediately with clean cold water.
If there is any further discomfort, seek prompt medical attention.
Wash your hands immediately after performing this maintenance.
Note :
NEVER add additional acid, add only distilled water.