14.2
Parameter Axis: Settings
Table 6: List of general axis parameters
Function
Range
Default Setting
Axis type
Measuring system - - - drive outputs
Encoder - - - Digital
X
Encoder - - - PID + Digital
Analog - - - Digital
Encoder - - - Digital
Analog - - - Digital
Button manual mode
normal, inverted, off
normal
Drive signal configuration
Mode 1, 2, 3, 4, 5, 6, 7, 8
Mode 2
Reference mode
Mode 1, 2, 3, 4, 5, 6, 7, 8
Mode 1
Spindle compensation mode
without
with s/-
forced loop +/-
without
Software end-position
both enabled
negative disabled
positive disabled
both
disabled
both enabled
Hardware end-position
both enabled
negative disabled
positive disabled
both disabled
both enabled
Retract mode
Mode 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
Modus 1
Error compensation
off/on
off
Piece counter
without
auto decrement
auto dec stop
auto increment
auto decrement / increment
decrement
dec stop
increment
decrement / increment
auto decrement
Incremental positioning
off/on
on
Decimal point
without, 1/10, 1/100, 1/1000
1/10
Display option manual
left-right
down-up
forward-backward
left-right
Unit
mm / inch / degree
mm