10.2
System: System-Times
Next set stepping
This is the time setting in seconds (0.0 … 9.9) how long the controller should wait in the program-mode,
with auxiliary counter “auto-program” until the next set is positioned.
Clamping off
If the function „clamping off“ is assigned to an output (system
I/O-configuration
output function),
the controller is waiting between setting the output and the start of positioning, as well as between reset-
ting the output (after completion of positioning) and the release of the next action for the specified time
(0.0 … 9.9 s). This function is used to release (activate) e. g. a clamping system or brake right before (af-
ter) positioning.
Edit-mode timeout (no PIN necessary)
This is the time until exiting the input mode (0.0 … 9.9 s, default setting: 2.0 s)
Piece counter program
Here the time is defined in seconds (0.0 … 9.9), which presents the signal “quantity reached” in the pro-
gram mode. If the values = 0, the output “quantity reached is set statically.
Clamp auxiliary function
If the program mode „next program step“ has been chosen and the parameter system
setup
options
auxiliary function setting is „on“, the auxiliary function outputs are hold for the defined time (0.0 … 9.9
in seconds). After this it is switched to the next set.
Next set stepping
Clamping off
Editmode timeout
Piece counter prog
Clamp aux function
Setup
Access to the system parameters
System-Times
Access to system parameters concerning times
I/O-configuration
Here the inputs and outputs can be assigned
Default parameter
Reset the parameters to factory settings