Axis Menu
- 35 -
calib measuring system
0.0
X inc
90.0
90.0
0
4095
4095
+
min
max
act
9.5
Parameter Axis: Measuring System - optional
This menu is used to calibrate analog inputs. The submenu "measuring system" is only relevant for devices which
are optionally equipped with an analog input (
Please note:
The submenu "Measuring system" appears only under "Axis parameters", if an analog measuring system has
been assigned to the corresponding axis (parameter axis
X-/Y-axis
settings
axis type
IN ).
See also figure 11 and table
Figure 11: Assigning an analog input to an axis
9.5.1
Analog Input Calibration
A minimum and a maximum value for the lower voltage (offset) as
well as the upper voltage (full scale) of the analog measuring system
can be set during calibration.
The analogue input is designed for 0 ... 3.3 V, whereby 3.3 volts
correspond to the full scale of 4095 increments (12 bits).
Example factory setting (see figure 12):
Min value: 0 V
≙
0.0 mm
Max value: 3.3 V
≙
90.0 mm
Figure 12: Analog Input Calibration
With these two buttons, the minimum and maximum positions of the analog axis can be man-
ually approached in the desired direction in order to calibrate them.
Used as a teach button: After approaching the “min” and “max” position, the incremental
measured value is assigned to the position, written into the corresponding field and stored.
See also section
X-axis system 1/14
IN axis type OUT
Analog ---
Digital
F1
F3
F2
Distances
Access to parameters concerning distances e.g. speeds etc.
Times
Access to parameters concerning times e.g. position reached, zero speed monitoring, rotary encoder etc.
Measuring system
.
To calibrate analog measuring systems
Settings
Access to the general axis parameters
Measuring system calibration