Axis Menu
- 25 -
Position reached
The output signal is statically if this time parameter is set to 0 or wiping if a time is defined here. The
output will be active as soon the according axis has reached the target position.
Spindle compensation
In the peak of the loop drive the drive signals switch off. The controller returns to the target value when
the parameterized time has expired (adjustment range 0.0 … 99.9 s). With a setting of “0” there is no
waiting period at the peak.
Manual change
After expiration of this time, the manual mode switches from the low speed to the next higher speed.
Monitoring
Defines a time within a range of 0.0 ... 99.9 s to monitor the encoder resp. measuring system. If there
are no encoder signals during the programmed period of time, the drive signals are switched off to stop
the engine. With a etting of “0” the monitoring is deactivated.
Delay control enable
After the START command the output “control enable” is activated. After reaching the target position
and only after the expiration of the programmed time (range 0.0 … 99.9 s) in the parameter delay
contr.enable the output is set back. With a etting of “0”, the output for the control enable is adjusted
statically and remains active until the operation modes changes resp. until STOP key is pressed.
Start delay
At a START command the start of the positioning is delayed for the entered time.
Shutdown control
Here the time for shutdown after the position is reached is entered (range 0.0 ... 99.9 s).
Retract time
The dwell-time at the peak is entered here (range 0.0 …99.9 s). After this time has been expired, the
position control is set back from the retract peak to the target value. In addition this value is also used
for a retraction on time.
Delay retract
The retraction is delayed for the entered time.
Reference time
In the peak of the reference run the drive signals switch off. The controller will continue positioning after
this time has been expired (range 0.1 ... 99.9 s).
Quantity reached
This parameter is used to set a time for the signal “quantity reached” (range 0.1 ... 99.9 s).
With a setting of “0” the output “quantity reached” is statically set.
Содержание P40-000 Series
Страница 61: ...Accessories 61 Notes...
Страница 62: ...Accessories 62 Notes...