System Menu
- 43 -
Auxiliary function
In the single and program mode these outputs are set according to the defined time in parameter
system
system-times
clamp aux function
Clamping
This output is set before a positioning and is reset after a positioning (e. g. for a clamping system or
in order to activate resp. release the brake). The corresponding time can be defined in parameter
system
system-times
clamping off
All axes on position (only two-axis version)
If both current actual values correspond to the according target pos/- the value entered in
parameter axis
X-/Y-axis
distances
tolerancewindow, this output is set.
Retract s1 axis
This output is active during retract.
10.3.3
Input and Output Configuration
The inputs and outputs with their associated logic can be configured freely.
10.3.3.1
Linking of Inputs with Functions
Chapter
15 I/O Configuration Notation Table contains an overview of all functions which can be assigned to
the inputs. After selecting a function via parameter system
I/O-configuration
input function by using the
navigation buttons. The desired input for this function can be selected by pressing the ENTER button.
If a previously used input needs to be reset, the button can be used, to set the input to the “not used” state.
Further it is possible to press the ENTER key repeatedly until “not-used” appears in the display. A multiple use of
inputs is not possible here. If an input is already used, only the next free input can be chosen automatically.
Figure 13: Input assignment
10.3.3.2
Input Logic Assignment
After the inputs of the controller have been assigned with functions, parameter system
I/O-configuration
input logic can be used to determine whether the corresponding input function should be triggered to a logic
HIGH level or a logic LOW level. The logic is assigned by selecting the corresponding function and pressing the
ENTER button.
IN assignment 1/26
switch endpos X-min
ST4 (S14) - P03
switch endpos X-max
not used
switch endpos Y-min
not used
IN logic 1/26
switch endpos X-min
l
ow active
switch endpos X-max
low active
switch endpos Y-min
low active
Содержание P40-000 Series
Страница 61: ...Accessories 61 Notes...