-99-
•
Avoid installing in rooms with lined, insulating or sound
deadening drapes.
•
Avoid installing in rooms with closed wooden window shutters inside.
•
Avoid installing in the corners of a room.
The EL-2606 is best suited to rooms with moderate noise.
,
The sensor may not consistently detect cracks in the glass, bullets which break through
the glass or glass breaking around corners and in other rooms. Glassbreak sensors
should always be backed up by interior protection.
For best false alarm immunity:
•
Locate the sensor at least 1.2m away from noise sources (televisions,
speakers, sinks, doors, etc.).
•
Avoid rooms smaller than 3m x 3m and rooms with multiple
noise sources.
•
Do not use where white noise, such as air compressor noise, is
present (a blast of compressed air may cause a false alarm).
•
Do not define the zone as 24hr. It is recommended to register the EL-
2606 to a perimeter arming group that arms the perimeter doors and
windows of the premises.
•
Avoid humid rooms – the EL-2606 is not hermetically sealed. Excess
moisture can eventually cause a short and a false alarm.
Areas to avoid:
•
Glass airlocks and
glass vestibule areas
•
Noisy
kitchens
•
Residential
car
garages
•
Small utility rooms
•
Stairwells
•
Small
bathrooms
•
Other
small
acoustically live
rooms
For glass break protection in such applications, use shock sensors on the windows or window
frames connected to an EL-2602 universal transmitter.
Installation Procedure
Figure B.7: EL-2606 (cover off)
Tamper
Switch
Battery
Holder
Antenna
Terminal
Block
LED
Indicator
Mounting
Knockout
Mounting
Knockout
Acoustic
Sensor
Содержание infinite prime
Страница 1: ......
Страница 86: ... 86 Appendix A Menu Structure Legend Installer code required Master code required ...
Страница 87: ... 87 ...
Страница 88: ... 88 ...
Страница 89: ... 89 ...
Страница 90: ... 90 ...
Страница 91: ... 91 ...
Страница 92: ... 92 ...
Страница 112: ......
Страница 113: ...Copyright 2008 Electronics Line 3000 Ltd All rights reserved ...