-78-
10.9.2: Restore Reporting
For each event group, you can determine whether restore messages shall be sent.
To enable/disable restore reporting for an event group.
1. From the Programming menu, select Communications, Event Options [955].
2. Select an event group.
3. From the event group’s sub-menu, select Report Restore [#2].
4. Select Enabled or Disabled.
10.9.3: Two-Way Audio
For Burglary, Fire and Medical event groups, there is an additional option that enables
Two-Way Audio for that event group –
see 5.2.2: TWA Alarm Reporting.
To enable/disable Two-Way Audio for an event group:
1. From the Programming menu, select Communications, Event Options [955].
2. Select an Event Group (Burglary, Fire or Medical).
3. Select TWA [#3].
4. Select Enabled or Disabled.
10.10: Vocal Message Dialer Event Options
Events reported using the Vocal Message Dialer are divided into event groups that
correspond with the pre-recorded event messages. This allows you to enable or disable
the Vocal Message feature for a specific group of events. For further information on this
feature,
see 10.3: Vocal Message Dialer
.
The vocal message event groups and their associated system events are as follows:
•
Burglary
[#1]
o
Alarm from Zone (excluding Gas and Environmental zones)
o
Zone
Tamper
o
Tamper
o
Duress
•
Fire
[#2]
o
Zone Fire Alarm
o
User Activated Fire Alarm
•
Panic
[#3]
o
Zone Panic Alarm
o
User Activated Panic Alarm
•
Medical
[#4]
o
Zone Medical Alarm
o
User Activated Medical Alarm
o
No
Motion
•
System Trouble [#5]
o
Battery
Low
o
Transmitter Low Battery
o
AC
Loss
o
Media
Loss
o
Device
Trouble
o
Communication
Trouble
Содержание infinite prime
Страница 1: ......
Страница 86: ... 86 Appendix A Menu Structure Legend Installer code required Master code required ...
Страница 87: ... 87 ...
Страница 88: ... 88 ...
Страница 89: ... 89 ...
Страница 90: ... 90 ...
Страница 91: ... 91 ...
Страница 92: ... 92 ...
Страница 112: ......
Страница 113: ...Copyright 2008 Electronics Line 3000 Ltd All rights reserved ...