-59-
To program the Keyfob Arm option:
1. From the Programming menu, select System Options, Arm/Disarm, KF Arm [94036].
2. Select With Exit Delay or No Exit Delay.
3. Press
when the desired setting is displayed.
9.4: Panic Alarm
SOS Panic alarms generated from the front panel, keypads or keyfobs can be defined as
either audible or silent.
To program the Panic Alarm setting:
1. From the Programming menu, select System Options, Panic Alarm [9404].
2. Select Audible or Silent.
9.5: AC Loss Delay
The AC Loss Delay is the amount of time that has to elapse before an AC Loss report is
sent to the central station. If AC power is restored before the event message is sent, the
event message is cancelled and will not be sent. You can program an AC Loss Delay to
be between 1 and 255 minutes after the system first senses the AC loss condition.
Alternatively you can program a random AC Loss Delay.
The AC Restore message is also sent using the same method described above. AC
Restore is reported only if the AC Loss report was sent.
To program the AC Loss Delay:
1. From the Programming menu, select System Options, AC Loss Delay [9405].
2. Enter a delay time (001-255 minutes) or enter 000 if you require the system to
choose a random AC Loss Delay.
3. Press
when the desired setting is displayed.
9.5.1: Random AC Loss Delay
In the event of AC loss, an event message is sent to the central station between 15 and
30 minutes after the AC loss condition is sensed. The system chooses this delay at
random in order to prevent the central station being inundated by simultaneous AC Loss
reports in the event of a regional power cut.
9.6: Display Options
The following options relate to the information the system displays on the LCD keypad.
9.6.1: Arm Status Display
The Arm Status Display includes the current arm status and any trouble conditions that
may exist within the system. You can program the system to display this information at all
times or only for two minutes after arming or disarming the system.
To program the Arm Status Display options:
1. From the Programming menu, select System Options, Display, Arm Status [94061].
2. Select Display Always or Display 2 Min.
9.6.2: Banner
The Banner is the 16-character text that you can program to appear on the top row of the
LCD display. This text replaces the arm status if it is programmed to display for two
minutes only –
see 9.6.1: Arm Status Display.
Содержание infinite prime
Страница 1: ......
Страница 86: ... 86 Appendix A Menu Structure Legend Installer code required Master code required ...
Страница 87: ... 87 ...
Страница 88: ... 88 ...
Страница 89: ... 89 ...
Страница 90: ... 90 ...
Страница 91: ... 91 ...
Страница 92: ... 92 ...
Страница 112: ......
Страница 113: ...Copyright 2008 Electronics Line 3000 Ltd All rights reserved ...