-100-
1. Open the housing using a small flat-head screwdriver to separate the
base from the cover.
2. Remove the insulator separating the battery from the contacts on the
battery holder. When you apply power and the Tamper switch is open,
the EL-2606 enters Test mode during which a transmission is sent
every few seconds. You can terminate Test mode by closing the
Tamper switch. Test mode is automatically terminated after
approximately five minutes.
3. From the Programming menu, select Devices, Zones [911].
4. Select the zone to which you want to register the transmitter; the system
initiates Registration mode. When
Save?
appears on the control system’s
LCD display, press
.
5. After registration, press the EL-2606’s tamper switch to terminate
Test mode.
6. Choose a suitable mounting location according to the guidelines in the
previous section.
7. Before permanently mounting the unit, test the acoustic sensor and the
transmitter from the exact mounting position. For further information on testing
the acoustic sensor, refer to the following section, Testing Procedures.
8. Knock out the required mounting holes on the back cover.
9. Mount the unit to the wall using the mounting screws provided.
10. Write the number of the zone on the sticker provided and affix the
sticker inside the front cover for future reference.
11. Close the front cover making sure that it snaps shut.
Testing Procedure
The Pattern Recognition Technology™ of the
EL-2606 ignores most of the sounds that
could cause a false alarm (including glass-
break testers). In order to test the EL-2606,
you must set the unit to Test mode. In Test
mode, processing of the upper and lower
frequencies is disabled. This means that the
EL-2606 is only listening for mid-range
frequencies reproduced by the glassbreak
tester. It’s these mid-range frequencies that
determine the sensor’s range.
,
In Normal mode, the tester will not activate the sensor unless held directly over the sensor.
Test the sensor using the Electronics Line GBS7 or Sentrol 5709C hand-held tester.
1. If using the 5709C tester, set the tester to tempered glass. The 5709C
tester has a different setting for each type of glass. The tester should
always be set for tempered or laminated glass (either is correct and both
have the same range) unless the installer is certain that all the glass to
be protected is plate glass.
2. Hold the tester speaker directly on top of the sensor and activate the
tester; the sensor generates an alarm and then enters test mode for
one minute. When in test mode, the LED on the sensor flashes
continuously. You can extend the test mode time by firing the tester at
the sensor at least once a minute.
Figure B.8: Testing the EL-2606
Содержание infinite prime
Страница 1: ......
Страница 86: ... 86 Appendix A Menu Structure Legend Installer code required Master code required ...
Страница 87: ... 87 ...
Страница 88: ... 88 ...
Страница 89: ... 89 ...
Страница 90: ... 90 ...
Страница 91: ... 91 ...
Страница 92: ... 92 ...
Страница 112: ......
Страница 113: ...Copyright 2008 Electronics Line 3000 Ltd All rights reserved ...