For example, if the shutter moves UP (A), it is stopped initially when pressing the button
for the opposite direction (B) and DOWN when pressing the button (B) again.
Keycode A: UP/STOP
Keycode C: UP/STOP
Keycode B: DOWN/STOP
Keycode D: DOWN/STOP
A, B as well as C and D are assigned automatically. Only one of these keycodes must
be programmed. Both groups can be used separately.
UP/STOP/DOWN (3-button operation)
This operating mode is only available with receivers for shutter control featuring two
interlocked relay outputs. Here, UP stands for switching of the 1st relay, DOWN for
switching of the 2nd relay. The relays automatically cut off again after 90 seconds.
Parallel switching of both outputs is not possible.
The STOP command is triggered by transmitting the keycode C or D.
Keycode A: UP
Keycode C: STOP
Keycode B: DOWN
Keycode D: STOP
A, B as well as C and D are assigned automatically. Only one of these keycodes must
be programmed.
IMPULSE
With this operating mode, the relay output is switched for 1 second upon receipt of a
programmed send code and afterwards releases again, independently of how long the
manual transmitter is operated.
Keycode A: ON (1 second)
Keycode C: ON (1 second)
Keycode B: ON (1 second)
Keycode D: ON (1 second)
Each keycode can be programmed and used separately. There is no automatic as-
signment.