33
Programming manual
3
0
The terminalcode for the bar code scanner
0 – terminal CR and LF
1 – terminal CR
2 – terminal LF
4
0
1st Scale port number
0 – device is not used
1..4 – RS-232 port number (COM1-COM4)
5
0
Communication protocol for 1st electronic scale
0 - CAS Morcan, MARTES T
1 - Euro scales, MARTES M
2 - Macca K
3 - Dibal
4 - Motex R
6 - Mettler Toledo
7 - ACOM
8 - CAS Morcan TP2
6
0
2nd Scale port number
0 - device is not used
1 - 4 RS-232 port number (COM1-COM4)
7
0
Communication protocol for 2nd electronic scale
Same as „Communication protocol for 1st
electronic scale
Two and more devices can´t be assigned in figure 5a) and figure 5b) to the same serial port. Port number 5 (USB) and 6
(RS-485) shares pins with COM2 port.
If cash register is connected to PC via USB port, to COM2 port cannot be connected any other device. Also at communi-
cating trough RS485, the USB communication will not work.
Flag 5 c) - External RS-485 converter settings
Figure 3.5 c) Fifth c) system flag values
Digit Default setting Meaning
Valid values
1
0
External RS-485 converter using
0 - no, 1 - yes
2
1
Active level of signal for RS-485 converter control
0, 1
3-6
0000
Time in tenths of µs [µs x 10], which ECR has to
wait before packet sending
0 - 2 000 i.e. 0 - 20 000 [µs]
Flag 5 d) - Clean cash comminication port settings
Figure 3.5 d) Fifth d system flag values
Digit Default setting Meaning
Valid values
1
1
Port for communication with CleanCash
1 - 4 - COM 1 to COM 4
7 - if Clean Cash is connected through
JODO
2
2
Programming communication speed for CleanCash
0 – 9600,
1 – 19200,
2 – 38400
Содержание Euro-200TE
Страница 1: ...Euro 200TE User manual Swedish version 1 1...
Страница 8: ......
Страница 9: ...INTRODUCTION...
Страница 15: ...CASH REGISTER CHARACTERISTICS...
Страница 27: ...PROGRAMMING MANUAL...
Страница 58: ......
Страница 59: ...OPERATION IN REGISTRATION MODE...
Страница 85: ...REPORTS...
Страница 100: ......
Страница 101: ...EURO2A SOFTWARE...
Страница 103: ...OPTIONAL ECR ACCESSORIES...
Страница 107: ...HELPFUL ADVICE...
Страница 114: ...114 Note...