TRT-BA-PC200-TC220630TTRT01-008-EN
PC 200
EN
OPERATING MANUAL
PARTICLE COUNTER
Страница 1: ...TRT BA PC200 TC220630TTRT01 008 EN PC 200 EN OPERATING MANUAL PARTICLE COUNTER...
Страница 2: ...ng manual must be observed You can download the current version of the operating manual and the EU declaration of conformity via the following link PC200 https hub trotec com id 40285 Definitions Term...
Страница 3: ...autions were taken at the surveyed location e g when performing measurements along public roads on building sites etc Otherwise do not use the device Observe the storage and operating conditions see T...
Страница 4: ...he particle counter sucks in air for an adjustable amount of time and determines the size and amount of particles contained in it Particles of the sizes 0 3 m 0 5 m 1 0 m 2 5 m 5 0 m and 10 0 m are tr...
Страница 5: ...r the respective channel were determined on the basis of ISO 14644 1 and in connection with practical experience values They are in no way legally binding and have a merely orientating function Device...
Страница 6: ...or 4 minutes Parameter Value Temperature measurement Temperature range 0 C to 50 C 32 F to 122 F Temperature accuracy 0 5 C 0 9 F at 10 C to 40 C 50 F to 104 F 1 0 C 1 8 F in other temperature ranges...
Страница 7: ...ght For storing the device use the transport case included in the scope of delivery in order to protect the device from external influences the storage temperature complies with the values specified i...
Страница 8: ...icator 17 Start delay Measurement duration Measurement interval 18 Indicator scale for particle burden 19 Size and amount of particles 20 Relative humidity 21 Wet bulb temperature 22 Dew point 23 Temp...
Страница 9: ...ement data 3 Press the RUN STOP button Depending on the configuration start delay measurement duration and measurement interval are shown consecutively The number of measured particles and their size...
Страница 10: ...TER button 4 Use the buttons to select activate to activate the filter efficiency mode activate deactivate 5 Press ESC to return to the Measurement screen 6 Press RUN STOP to start the measurement Onc...
Страница 11: ...pport on that score Trotec accepts no liability concerning the use of this free software and is under no obligation to make adjustments or to further develop updates or upgrades Connecting a USB cable...
Страница 12: ...otos videos and measurement logs on the internal memory or on the microSD card remain unaffected Disposal Always dispose of packing materials in an environmentally friendly manner and in accordance wi...
Страница 13: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...