39
Chapter 4 SelfCalibration
7. Choose “Gamma”, and press
.
Setting
Function
1.6-2.7
Set the gamma value.
Adobe®RGB
Set the gamma curve defined by Adobe®RGB.
sRGB
Set the gamma curve defined by sRGB.
EBU
Set the gamma curve defined by EBU.
REC709
Set the gamma curve defined by REC709.
REC1886
Set the gamma curve defined by REC1886.
SMPTE-C
Set the gamma curve defined by SMPTE-C.
DCI
Set the gamma curve defined by DCI.
L*
Set the perceptually uniform gamma curve defined by CIE1976.
Note
•
The color gradation adjustment results are reflected and automatically become “Fixed” when adjusted
with ColorNavigator 6.
Press
after completing the setting.
8. After completing all settings, press
.
4-5. Executing SelfCalibration
SelfCalibration can be executed manually regardless of the schedule.
Procedure
1. Choose “SelfCalibration” from the Adjustment menu, and press
.
2. Choose “Execute” from “SelfCalibration”, and press
.
The built-in calibration sensor is activated, and SelfCalibration is executed.
Attention
•
To execute SelfCalibration, it is necessary to set the calibration details. For more information,
see
“4-4. Setting the calibration targets” (page 38)
•
After selecting “Execute”, warming up (after the power to the monitor is switched on, leaving the monitor on
for a certain period of time until the display becomes stable) may be executed before the built-in calibration
sensor comes out.