AX M2 Series 3-5 kW | Solar inverter
Solar inverter | V1.7
Control and display elements - Page 38
16
Priority of the
charging source:
SbL: Solar energy first for
battery
UCb: Charging of the
battery with the mains
supply permitted
PV charging mode
(priority): only if solar
energy is not available
is the mains charging
mode is activated.
SbL: Solar energy first for
battery
UdC: Charging of the battery
with the mains supply
permitted
Only PV charging mode
(priority).
No mains charging
mode permitted.
SLb: Solar energy first for the
load
UCb: Charging of the battery
with the mains supply
permitted
PV energy supplies the
load first, and the
mains charging mode
is permitted.
SLb: Solar energy first for the
load
UdC: Charging of the
battery with the mains
supply permitted
PV energy supplies the
load first. No mains
charging mode is
permitted.