Troubleshooting & Fault Clearance
–
Page 115
Solar inverter | V1.7
The buzzer beeps. After 10 minutes, the inverter
stops charging and discharging the lithium
battery.
The loss of communication occurs once the
inverter and the battery are successfully
connected. The buzzer sounds immediately.
If the battery status cannot be charged through
successful communication between the inverter and
the battery, code 69 is displayed to stop the charging
of the battery.
If the battery status must be charged after the
communication between the inverter and the
battery was successful, code 70 is displayed for
the charging of the battery.
If the battery status cannot be discharged through
successful communication between the inverter and
the battery, code 71 is displayed to stop the
discharging of the battery.
11.3
USB error message
When an error occurs, the error code is only displayed for 5 seconds. After 5 seconds,
the display automatically returns to the display screen.
Error
Description
No USB device is recognized.
USB hard drive.
Document in USB device in incorrect format.