Innovating power.
AX M2 Series 3-5 kW | Solar inverter
Solar inverter | V1.7
Control and display elements - Page 32
6.2
Program overview
Program
number
Description
Options
00
Leaving the setting
mode
USB: Utility
first (preset)
The inverter
predominantly supplies
the loads with power.
If mains power is not
available, solar power
and batteries
predominantly supply the
loads with power.
Solar energy
predominantly supplies
the loads with power.
01
Priority, source of
the load supply
SUB: Solar first
If the solar energy is not
sufficient to supply all
connected loads, the
mains power supply
provides the loads with
power at the same time.
The battery only supplies
the loads with power
when solar energy and
and mains power are not
sufficient.
SBU priority
Solar energy
predominantly supplies
the loads with power.
If the solar energy is not
sufficient to supply all
connected loads, the
battery power supplies
Содержание AX M2 Series