Innovating power.
Control and display elements
–
Page 29
Solar inverter | V1.7
Output information
Displays the battery charge status with 0-24 %,
25-49 %, 50-74 % and 75-100 % in the battery mode and the
charging status in the mains mode.
In the AC mode, it displays the battery charging status.
Status
Battery voltage
LC display
I-phase during
the battery
charging
<2V/cell
4 bars blink alternatingly.
2 ~ 2.83V/cell
The lower bar is lighted and the
other three bars blink alternatingly.
2.083 ~ 2.167V/cell
Both lower bars are lighted and
the other two bars blink
alternately.
> 2.167 V/cell
The three lower bars are lighted and
the upper bar blinks.
Charge retention mode. Batteries are fully
charged.
4x bars are lighted.
Charging information
Displays an overload.
Displays the utilization rate with 0
–
24 %, 25
–
49 %, 50
–
74 %
and 75
–
100 %.
0%~24%
25%~49%
50%~74%
75%~100%
In the battery mode, the battery capacity is displayed.
Load in %
Battery voltage
LCD display
>50%
< 1.85V/cell
1.85V/cell~ 1.933V/cell
1.933V/cell~ 2.017V/cell