A NORDSON COMPANY
Ultra TT User's Guide
Version 1.2
9 I/O
The Ultra TT has 16 general-purpose inputs and 16 general-purpose outputs. The discrete I/O's
available include: 1 analog input/output, 2 digital inputs / 2 digital outputs and 2 solenoid drivers.
The Output instruction is available in the Select Instruction drop-down menu. It will allow the User
to insert an instruction into the dispense program that will assert or negate up to three specified
output bits. Please contact your local EFD Representative for instructions manuals if you would
like to create the logic scripts and to load inputs in your application.
10
MAINTENANCE
10.1
CLEANING
Use a soft lint-free cloth to wipe the exterior of the Ultra TT machine. A commercial stainless steel
cleaner e.g. Rubbermaid Professional Plus Stainless Steel Cleaner, may be used on the stainless
portions of the machine. Be sure to wipe down the cleaner completely.
10.2
PREVENTIVE MAINTENANCE
Annual preventive maintenance is recommended as follows. Prior to performing any maintenance
procedure, the machine should be unplugged and the power cord made visible to the User
performing the maintenance. Be sure to read all MSDS sheets prior to handling the lubricants and
take all required safety precautions.
The following items and instructions are included in PN7001PM-KIT are required to perform the
preventive maintenance.
• Safety glasses
• Rubber gloves
• Soft lint-free clothe
• Phillips screw driver
• 1.5mm hex wrench
• 3.0mm hex wrench
• Linear bearing grease
• Cable grease
A. Lubrication of Guide Rails
i. Remove X & Y axis covers.
ii. Use a lint-free cloth to wipe down LM Guide Rails.
iii. Apply a light coat of grease (NSK Brand Multi temp PS2) to guide rails.
iv. Manually move each axis back and forth the entire length of the rail four (4) times.
v. Wipe away any excess grease.
59