A NORDSON COMPANY
Ultra TT User's Guide
Version 1.2
2.5
VALVE/SYRINGE BARREL CONNECTIONS
The following chart summarizes how different EFD valves/syringe barrels should be connected to
the Z-head. Note that if more than one valve/syringe barrel is required for the application, a separate
dispenser controller for each addition will be required.
The Ultra TT system is a self-contained fluid-dispensing positioning system. It features integrated
dispensing functions to operate any EFD valve or syringe barrel. The valve/syringe barrel attaches to
the Z-carriage with the appropriate mounting fixture, and all pneumatic lines plug into the EFD
quick-connect on the top of the Z-head.
Note:
Your deposit size has a direct correlation to fluid pressure, time, tip size, dispense gap and
dispense speeds. To get desired results, you may need to experiment with different tip sizes,
dispense gaps, pressures and speeds.
It is important to review the material specification sheet of the fluid to be dispensed and ensure that
the proper personal protection equipment (such as footwear, gloves, etc.) is used with the type of
fluid dispensed.
The following chart summarizes how different EFD valves/syringe barrels should be connected to
the Z-head. Note that if more than one valve/syringe barrel is required for the application, a separate
dispenser controller for each addition will be required.
20
EFD Dispensing
Air Connection
Air Connection
Fluid Pressure Connection
Valve/Syringe barrel
(actuating)
(atomizing)
752V-UHSS
P1
N/A
P2 or Auxiliary Air
725DA-SS
P1
N/A
P2 or Auxiliary Air
725HF-SS
P1
N/A
P2 or Auxiliary Air
740V-SS
P1
N/A
P2 or Auxiliary Air
736HPA
P1
N/A
P2, Auxiliary Air or customer
supplied
780S-SS
P1
P2
Auxiliary Air
790
Terminal 1+
N/A
P2 Selectable between pulsed
Terminal 2 -
N/A
or constant pressure
Syringe barrel 0~100 psi
P1
N/A
Same as actuating
Syringe barrel 0 ~ 30 psi
P2
N/A
Same as actuating
5800MP
P1
N/A
Same as actuating
HP4X™
P1
N/A
Same as actuating
HP7X™
P1
N/A
Same as actuating
2800
N/A
N/A
N/A