A NORDSON COMPANY
Ultra TT User's Guide
Version 1.2
1.1.1
FRONT PANEL
14
P1 Gauge
&
Regulator
0 ~ 100PSI
LCD Menu
Scroll Knob
Emergency
Machine Off
(EMO)
Interactive
LCD
Interactive LCD
Soft Keys
Vacuum control
Ground Strap
Connector
RS232
PDA Connector
P2 Gauge
&
Regulator
0 ~ 30 psi
X/Y, Z/T
Jog Keys
Power
Button
P1:
0-100 psi pneumatic channel. To adjust the pressure, first unlock the pressure knob by pulling outward,
turn it to the right to increase pressure or left to reduce pressure. Push the knob inward to lock.
P2:
0-30 psi pneumatic channel. To adjust the pressure, first unlock the pressure knob by pulling outward,
turn it to the right to increase pressure or left to reduce pressure. Push the knob inward to lock
Vacuum control:
The vacuum is connected in parallel so both P1 & P2 channels can maintain a vacuum. To
adjust the vacuum pressure, turn the control knob to the left to increase vacuum and turn it right to decrease
vacuum.
Interactive LCD:
This is where you can view the current program selected, call up new programs, run tip
offsets or purge routines, pause or resume a program. The LCD also outputs user-defined messages along
with error messages. The arrow keys: X/Y, Z/T keys work in conjunction with the LCD that prompts the user
to either teach current position or teach new position for tip location at origin. The keys are selectable
between XY and ZT modes.
E-Stop:
The large red button with the yellow indicator shuts off power to all actuating devices such as
servomotors and pneumatic circuits. To reset power, you must turn the red button clockwise to release then
press the green button to restore power to the actuator. This button should only be used for real emergency
stops. If you want to abort a program, press the soft key directly beneath the word “abort” on the LCD panel.