A NORDSON COMPANY
Ultra TT User's Guide
Version 1.2
4.
Select the Assertion Level, which defines whether a “1” or a “0” written
to the Output Bit will cause the toggle bracket to move down.
5.
Tap “Up” or “Down” to test the toggle bracket for the proper Output Bit
and Assertion Level.
6.
Tap “OK” to return to the Setup screen.
7.
Now select “Actuation Output” from the Setup drop-down menu.
8.
The Valve Actuation configuration screen allows the user to select
which output will actuate the toggle, secondary or tertiary valve.
9.
Tap the down arrow and select the desired discrete output from
the drop-down menu. The EFD dispensing controller for the
toggle valve is connected to this discrete output. The
EXT_OUTPUT_A or EXT_OUTPUT_B are the preferred bits.
10.
Tap “OK” to return to save the settings before returning to the
Setup screen or “Cancel” to return to Setup screen without
saving.
Note that the default toggle delay value is 0.5 seconds. The delay is
used for both lowering the valve and for raising the valve. If you need to
change this delay, please contact your EFD Ultra TT Representative.
4.2
UNITS
Select the desired units to be displayed from the drop-down menu.
Options are in inches or millimeters.
32