![Edwards nEXT200200 Скачать руководство пользователя страница 79](http://html1.mh-extra.com/html/edwards/next200200/next200200_instruction-manual_2366136079.webp)
7.4 Clean the external surfaces of the pump
CAUTION: CLEANING SOLUTIONS
Risk of damage to equipment. Clean the external surfaces of the pump in a well-
ventilated location. When using cleaning solutions and solvents to clean the pump,
obey the precautions given by the manufacturer. Do not inhale particulates which can
be in the pump.
Do not clean the parts of the pump other than external surfaces. Use of organic
solvents can damage the internal pump components. Do not use abrasive materials
to clean the pump parts.
If the inner side of the pump is contaminated, it cannot be possible to get the necessary
ultimate vacuum performance or the pump-down times can increase. In this case, return
the pump to our Service Centre for cleaning.
You can use the organic solvent to clean the external surface of the pump. We
recommend you to use non-CFC solvents such as isopropanol or ethanol. Only small
amount of a cleaning solution is necessary to clean the pump surface.
For environmental reasons, keep wastage of cleaning solutions and solvents to a
minimum.