![Edwards nEXT200200 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/edwards/next200200/next200200_instruction-manual_2366136031.webp)
3.9 Logic interface connector
The pump has 15
‑
way logic interface connector at the end of the logic interface cable.
You can plug the logic interface connector into the manufacturer's TIC Turbo
Instrument Controller or TIC Turbo Controller. Use applicable connector mating half (not
supplied) to connect the pump to the customer equipment. Refer to
interface technical data on page 27
for the connector mating half type,
interface connector pins on page 28
for the logic interface connector pins for the
electrical connections and
Figure: Interface circuits for nEXT turbo pump controllers on
for the circuit diagrams of the connector interface.
Table 8
Logic interface technical data
Logic interface item
Connector*
15
‑
way D
‑
type male
nEXT pumps electrical supply:
Permitted voltage range
(with ripple)
24
‑
48 V d.c. +5%, -10%
(21.6 to 50.4 V d.c.)
Maximum voltage ripple
0.5 V r.m.s.
Fuse rating
10 A for 24 V d.c. supply
5 A to 10 A for 48 V d.c. supply
Type 'T' IEC approved or
Time delay fuse UL/CSA approved
Limit of the power supply:
Factory default setting
160 W
Maximum setting
200 W
Minimum setting
50 W
Precision of power regulation
± 10 W
Start and serial enable control inputs:
Enabled control voltage: low (close) 0 to 0.8 V d.c. (I
out
= 0.55 mA nominal)
Disabled control voltage: high
(open)
4 to 26.4 V d.c. (Internal pull up to
6.4 V nominal)
Standby control input
Enabled control voltage: low (close) 0 to 0.8 V d.c. (I
out
= 0.29 mA nominal)
Disabled control voltage: high
(open)
4 to 26.4 V d.c. (Internal pull up to
3.2 V nominal)
Analogue output
Output voltage
0 to 10 V d.c. (directly proportional to the
measured parameter)
Motor speed: 0
‑
1000 Hz (0
‑
100%)
Input power: 0
‑
200 W
Motor temperature: 0
‑
100 °C
Controller temperature: 0
‑
100 °C
Voltage precision
± 0.2 V
Output current
£
5 mA for specified precision
Page 27
B85200880_D - Technical data
Содержание nEXT200200
Страница 6: ...This page has been intentionally left blank...
Страница 24: ...Figure 3 nEXT 200200 NW25 interstage port pumping speed Page 20 B85200880_D Technical data...
Страница 77: ...6 8 Bakeout nEXT200200 split flow pumps are not applicable for bakeout Page 73 B85200880_D Operation...
Страница 100: ...edwardsvacuum com...