3.
Reboot the Sonar Firmware by double-clicking on the Sonar icon in the main Sonar Remote
Desktop Screen, as shown in
designated by green arrow.
4.
Now, plug in the devices into
COM 1
and
COM 2
. Which device is connected to which COM port
does not matter, as long as their respective ports and baud rates are set in Sonar.
5.
Click on
Misc.
at the top of the Sonar screen, as shown in
, then
Serial Port
Information.
6.
Check
COM1
and set the correct baud rate for that device using the dropdown menu shown in
. When the correct baud rate is set, the State should say
OK,
and
Errors
should not be increasing, as shown in
circled in green. The correct data string
should also be scrolling in the lower part of the window, as shown in
green arrow.
7.
Now Check
COM2
and set the correct baud rate for the other device as done before in Step 6.
8.
Now click on
File
>
Show Status
in the sonar window, as shown circled in red in
9.
On the right-hand side of the window, click on the
Config
bullet under the
Update
button and
then on the dropdown menu named
Config Item
10.
Select
Serial
from the dropdown menu (green arrow), then click on the
Update
button (blue
arrow) several times, as shown in
11.
Check to make sure sensors' usage percentages are well below 80%, as shown in
circled in purple. If they are not, increase the sensor’s baud rate. Change baud rate under
Serial
Port Information
as done in steps 6 and 7. Check
Status
again. Otherwise, sonar will report errors.
Содержание 6205S
Страница 27: ...2 10 Figure 2 5 Acoustic Center Location in X Y and Z and Bolt Pattern of Standard 6205s 0019604...
Страница 28: ...2 11 Figure 2 6 Acoustic Center Location in X Y and Z Dimensions and Bolt Pattern with Adaptor Flange 0021206...
Страница 37: ...3 20 Figure 3 5 6205s Exploded View with Adaptor Flange...
Страница 38: ...3 21 Figure 3 6 6205s Transducer...
Страница 40: ...3 23 Figure 3 8 6205s Wiring Diagram 0019627...
Страница 86: ...8 69 Figure 8 22 Checking all COM Ports...
Страница 92: ...8 75 Figure 8 28 UDP broadcast settings example Figure 8 29 Eth1 data output...
Страница 94: ...8 77 Figure 8 31 1PPS settings example Falling Edge and 1msec duration...