background image

8-62 

 

 

 

 

 

6205s BATHYMETRIC AND SIDE SCAN SONAR

 

0020300_REV_E

 

 

Figure 8-16: Checking Serial Port Information 

11.

 

Click 

File

 > 

Show Status

 in the sonar window, as shown circled in red i

FIGURE 

8-17

.  

 

Figure 8-17: Checking Sensor Status 

Содержание 6205S

Страница 1: ...EdgeTech 4 Little Brook Road West Wareham MA 02576 Tel 508 291 0057 Fax 508 291 2491 www EdgeTech com 6205S BATHYMETRY SIDE SCAN SYSTEM U S E R H A R D W A R E M A N U A L 0020300_REV_E 11 6 2020...

Страница 2: ...rights reserved Microsoft and Windows are registered trademarks of Microsoft Corporation Storm Case and Hardigg are trademarks of Pelican GETAC is a registered trademark of MiTAC Synnex Group HYPACK...

Страница 3: ...equipment described in this manual should read and understand the warnings and cautions provided below CAUTION This equipment contains devices that are extremely sensitive to static electricity Theref...

Страница 4: ...the same software drivers if applicable At times however direct replacements may not exist When this happens EdgeTech will provide the necessary drivers with the replacement part if applicable EdgeTec...

Страница 5: ...tures may be periodically upgraded Therefore the information in this manual is subject to change and should be used for reference only Liability EdgeTech has made every effort to document the 6205s Ba...

Страница 6: ...The items have not been misused or abused in any manner nor have repairs been attempted thereon without the approval of EDGETECH CUSTOMER SERVICE iii Written notice of the failure within the warranty...

Страница 7: ...rted directly to the customer New software releases consist of the following Software enhancements that are not on the price list Software fixes and changes Product integration Documentation updates t...

Страница 8: ...ied on the invoice CAUTION Never attempt to ship a Portable Topside in its Storm CaseTM alone Although rugged these cases are not intended to be used as shipping containers and the delicate internal c...

Страница 9: ...erefore we encourage you to contact EdgeTech Customer Service to offer any suggestions or to request technical support NOTE Have your system Serial Number available when contacting Customer Service E...

Страница 10: ...estuarine and coastal applications for over 50 years The company has responded to the scientific Naval and offshore communities needs by providing equipment such as sub bottom profilers side scan son...

Страница 11: ...ncements vii RETURNED MATERIAL AUTHORIZATION viii RMA Purpose viii CUSTOMER SERVICE ix COMPANY BACKGROUND x TABLE OF CONTENTS xi LIST OF FIGURES xiv LIST OF TABLES xvii OVERVIEW 1 1 1 1 Applications 1...

Страница 12: ...side Computer Requirements Specifications 3 17 3 7 Deck Cable 3 18 3 8 Mechanical Drawings 3 19 CONNECTIONS AND FORMATS 4 24 4 1 Data Formats 4 24 4 2 System Connections and Data Flow 4 25 4 2 1 Ether...

Страница 13: ...for Redundant Information 8 54 8 2 1 Two Different Sensors Supplying the Same Message 8 54 8 2 2 Two Sensors Output Same Information with Different Messages 8 56 8 3 Configuring COM Ports 8 58 8 3 1...

Страница 14: ...igure 3 7 6205s Array Color Codes Diagram 3 22 Figure 3 8 6205s Wiring Diagram 0019627 3 23 Figure 4 1 6205s Rack Mount Topside Interface Connections 4 26 Figure 4 2 6205s R Rack Mount Topside Interfa...

Страница 15: ...g SV Data in Sonar exe 8 54 Figure 8 7 Configuration Menu 8 55 Figure 8 8 Auxiliary Sensors 8 55 Figure 8 9 Sonar Control Tab 8 56 Figure 8 10 SonarSer all ini 8 57 Figure 8 11 Sonar Remote Desktop Ap...

Страница 16: ...27 TimeSyncSource Keyword Adjustments 8 74 Figure 8 28 UDP broadcast settings example 8 75 Figure 8 29 Eth1 data output 8 75 Figure 8 30 Data packets required but at 25Hz or 50Hz not 1Hz 8 76 Figure...

Страница 17: ...BLES Table 3 1 Physical Specifications 3 12 Table 3 2 Acoustic Specifications 3 13 Table 3 3 Power Requirements 3 14 Table 3 4 Environmental Specifications 3 14 Table 3 5 6205s Topside Interface Speci...

Страница 18: ...h frequencies The bathymetry operates at either 230kHz or 550kHz Additionally EdgeTech s latest 2205 Electronics and Modular Arrays are utilized in the 6205s resulting in an extremely lightweight desi...

Страница 19: ...Hz Bathymetry Data 550 1600 kHz Dual Frequency Side Scan with 550 kHz Bathymetry Data The modular design of the 6205s allows for multi frequency bathymetry options in a single sonar head The field exc...

Страница 20: ...umber of topsides CARIS HIPS SIPS supports our native JSF files for post processing For questions on Third Party Interfacing with Discover Bathymetry refer to THIRD PARTY SOFTWARE Contact EDGETECH CUS...

Страница 21: ...Bathymetry Data 550 1600 kHz Dual Frequency Side Scan with 550 kHz Bathymetry Data The frequency sets listed above were chosen to provide optimum results for any given water depth up to 200m 660ft be...

Страница 22: ...Sonar Head Components NOTE The terms used in Figure 2 1 are referenced throughout this manual HOUSING MOUNTING PLATE SONAR PROCESSOR SOUND VELOCITY SENSOR SVS SONAR ARRAYS PORT and STBD HOUSING SONAR...

Страница 23: ...tallation and mobilization time The variable bolt pattern is shown in FIGURE 2 3 EdgeTech advises mounting the 6205s Sonar Head to the bow of a survey vessel By placing the system at the bow the sonar...

Страница 24: ...built in Windows 7 Embedded PC The main firmware installed on the embedded PC is called Sonar exe which controls the sonar s hardware and performs specific functions such as signal processing and time...

Страница 25: ...2 8 6205s BATHYMETRIC AND SIDE SCAN SONAR 0020300_REV_E Figure 2 4 6205s Electronics Housing and Arrays Installed...

Страница 26: ...ten elements make an approximately half wavelength spaced array of sensors for its bathymetry receiver 2 1 6 Acoustic Center The individual acoustic centers of each array port and starboard converge a...

Страница 27: ...2 10 Figure 2 5 Acoustic Center Location in X Y and Z and Bolt Pattern of Standard 6205s 0019604...

Страница 28: ...2 11 Figure 2 6 Acoustic Center Location in X Y and Z Dimensions and Bolt Pattern with Adaptor Flange 0021206...

Страница 29: ...Specifications 3 2 Acoustic Specifications SONAR HEAD MODEL 230 550 KHZ SS 230 550 BATHY 550 1600 SS 550 KHZ BATHY SIDE SCAN SONAR Center Frequency 230 520 kHz 520 1610 kHz Range per Side 225 125 m 7...

Страница 30: ...quency 230 kHz 550 kHz 850 kHz 1600 kHz Horizontal Beamwidth 2 way 0 54 0 36 0 29 0 20 Range Resolution 30 mm 10 mm 9 mm 6 mm Max Range Dependent on environmental conditions absorption reverberation s...

Страница 31: ...W 15 x H 7 5 Weight 5 4 kg 12 lbs 13 6 kg 30 lbs Construction Aluminum Polyethylene Polyurethane Interfaces 1 1 PPS via BNC 1 Trigger In via BNC 4 100 BaseT Ethernet Ports 3 Serial RS 232 Ports 1 1 PP...

Страница 32: ...s are unidirectional however data cannot be transmitted from the 6205s to an external device All three com ports are isolated via a proprietary signal conditioning isolator board This ensures noise ge...

Страница 33: ...e Discover software application for the rack mount topside sonar interface box option Minimum computer requirements are found in sub section 3 6 3 of this manual If the 6205s R Rack Mount Topside Inte...

Страница 34: ...ents Specifications The topside computer must be able to run EdgeTech s Discover Bathymetric Acquisition Software and any additional third party software To do so it must include the following minimum...

Страница 35: ...additional software outside the provided EdgeTech and third party bathymetric software is NOT recommended Installing software other than those supplied can have undesirable effects such as poor and or...

Страница 36: ...3 19 3 8 Mechanical Drawings This section contains supporting drawings for the 6205s Swath Bathymetry and Dual Frequency Side Scan Sonar System Figure 3 4 6205s Exploded View...

Страница 37: ...3 20 Figure 3 5 6205s Exploded View with Adaptor Flange...

Страница 38: ...3 21 Figure 3 6 6205s Transducer...

Страница 39: ...sed on their operating frequency The color code is shown and described below Figure 3 7 6205s Array Color Codes Diagram COLOR CODES Color Code Blue 230 550SS 230 Bathy Red 230 550SS 550 Bathy Yellow 5...

Страница 40: ...3 23 Figure 3 8 6205s Wiring Diagram 0019627...

Страница 41: ...itch and heave data in TSS1 or EM1000 binary format minimum of 20Hz d Time sync data in NMEA format minimum of 1Hz e 1PPS TTL typically from the GNSS receiver Data may be supplied by 1 2 or 3 individu...

Страница 42: ...65 ft Deck Cable The 6205s sonar interface then connects to a topside computer via a standard RJ 45 ethernet plug The correct IP addresses for the sonar head and topside computer are listed below The...

Страница 43: ...ng utilized it can serve as a splitter for serial data The output ports pair with the serial ports located directly above them These ports are unidirectional 4 2 3 Hardware Connectivity FIGURE 4 1 is...

Страница 44: ...itude heading roll pitch and heave data over one serial connection such as a NovaTel ProPak 6 or Applanix POS MV RS232 data output not Ethernet data output As depicted in FIGURE 4 1 the sensor is conn...

Страница 45: ...4 UDP CONNECTIONS for more information on configuring 6205s for UDP data transfer FIGURE 4 2 depicts a sensor interface to the 6205s Sonar Interface that provides a time and 1PPS connection and a nav...

Страница 46: ...guration Pulse per second PPS is a feature in many GPS units to provide an accurate timing signal to synchronize various devices to a precise common clock The Edgetech 6205s R rack mounted and 6205s P...

Страница 47: ...ackages 4 2 4 Sonar Data Flow The Discover Bathymetric software acquisition package provides a way to control store and display the bathymetry and side scan sonar data Discover Bathymetric contains tw...

Страница 48: ...nal latency to the 6205s Sonar Head via the deck cable 3 Auxiliary data is then combined with the raw sonar data and instantaneous sound velocity SV measurements They are time stamped with a common va...

Страница 49: ...cy side scan data in real time The data may also be recorded as a JSF file if the user desires 6 The completed data package range angle dual frequency side scan and all auxiliary data is sent to the t...

Страница 50: ...noise fluctuations on the ground line of the subsea electronics This board isolates the sensitive subsea electronics from potentially noisy grounds provided by the trigger and serial port inputs Noise...

Страница 51: ...nents and inspect them Check the packing list and verify all the items on the list are included If any damage is found after unpacking the components immediately report it to the carrier and EdgeTech...

Страница 52: ...5s sonar head to the bow of the survey vessel An example of an over the bow deployment is depicted in the photographs in FIGURE 5 1 If help is needed with this type of installation do not hesitate to...

Страница 53: ...the images in FIGURE 5 2 If help is needed with this type of installation contact EDGETECH CUSTOMER SERVICE Figure 5 2 6205s Deployment Option 2 Over the Side 5 2 3 USV Deployment An alternative to t...

Страница 54: ...build up can occur and viewing status indicators can become difficult to see due to brightness and glare The topside interface box can be set up in several ways depending on the model purchased The 6...

Страница 55: ...array For instance if the Sonar Head is configured as a 230 kHz 550 kHz Side Scan with 230 kHz bathymetry and the user wants to exchange the bathymetry frequency to the 550 kHz channel then the follow...

Страница 56: ...p the 6205s over so the bottom of the unit is upright to expose the remaining brackets Figure 5 6 Top Housing and Deck Cable Removed 4 Remove the 4 screws in the widest center bracket 5 Then remove th...

Страница 57: ...You DO have to remove the shell from which the black pigtail comes from You DO NOT have the remove the front shell 6 Slide the shell off the housing Figure 5 8 Remove the Portion of the Shell EdgeTech...

Страница 58: ...5 41 Figure 5 9 The Disconnected Bathymetry and Side Scan Sonar Cables 8 Remove all six 1 4 20 x 1 5 cap screws using the same 3 16 Allen key Figure 5 10 Remove the 6 Cap Screws...

Страница 59: ...ansducer slide it away from the Housing and pull it straight out of the frame Take care not to damage the side scan and bathymetry cables out of the frame Figure 5 12 Remove the Existing Transducer 10...

Страница 60: ...rently uses 12 Repeat the same steps for the opposite transducer CAUTION Each array is labeled according to the side it corresponds to Ensure the port array is installed on the port side and the starb...

Страница 61: ...the supporting data if a device is not connected properly If this is the case Discover Bathymetric will display its diagnostic window and show which serial port is causing the error It is not recommen...

Страница 62: ...op to Sonar application on the desktop screen If prompted for a password input admin Once logged on the Sonar Application will be displayed on the screen as shown in FIGURE 6 2 This window represents...

Страница 63: ...eable on COM1 and COM2 as long as the appropriate baud rate is set in the dropdown menu next to channel assignment in Serial Port Information Window as shown in Figure 6 4 red arrow More information o...

Страница 64: ...Port Information Window 4 Click on Menu File Show Status The System Status window will appear 5 At the bottom of the window click the Config bullet then the dropdown menu item named Config Item 6 Sele...

Страница 65: ...FIGURE 6 5 Figure 6 5 Sensor Usage Percentage Check 7 If they are not increase the baud rates of the sensors until these percentages drop Make sure to change the baud rate accordingly in Sonar 8 When...

Страница 66: ...TK Tide measurements can be incorporated into the 6205s System Most third party software packages can set up a device driver to acquire these data A 1PPS sync is needed in this case as these measureme...

Страница 67: ...may degrade the 6205s system s measurements and or the sound velocity sensor at the bottom of the Sonar Head If fouling is observed clean them using a washcloth with mild soap and freshwater The SVS m...

Страница 68: ...on Port 4 If this error persists longer than 30 seconds follow the procedure below to resolve the issue 1 Place the Sonar Head in water deep enough to submerge the SV probe the bottom half of the shel...

Страница 69: ...d check Chan 4 on COM 4 again as in step 4 above 7 If the port reports data then proceed to normal operation If not continue to step 8 8 Closeout of Sonar exe by clicking on the X in the top right cor...

Страница 70: ...Type in SET SV FORMAT 42 and press Enter Type in SET SV ZEROSUPPRESSION 5 seconds and press Enter Type in SET SVAVERAGE 4 and press Enter Type in SET SAMPLE 1 S and press Enter Type in SET DETECT 06...

Страница 71: ...the same information but from different messages The following subsections describe each problem and the configuration that should be done to remedy it In the event the auxiliary sensors cannot be rep...

Страница 72: ...8 55 1 Open the Auxiliary Sensors control dialog box Configuration menu Auxiliary Sensors as shown in FIGURE 8 7 and FIGURE 8 8 Figure 8 7 Configuration Menu Figure 8 8 Auxiliary Sensors...

Страница 73: ...message delivers roll pitch heading and heave to the 6205s Sonar Head with no way for the particular sensor to turn off any of these specific fields If a sensor like this is paired with another senso...

Страница 74: ...lated to reflect as shown in FIGURE 8 10 Figure 8 10 SonarSer all ini NOTE This new keyword disables the heading message from the OCTANS message The same can be done with an EM1000 binary format messa...

Страница 75: ...de and a time source For this type of configuration only COM1 will be utilized To configure the COM ports for one sensor 1 Turn on Topside PC and connect the 6205s via the deck cable to the 6205s Tops...

Страница 76: ...8 59 Figure 8 12 Finding the SonarSerial ini File Figure 8 13 SonarSerial ini File 6 Under Serial2 and Serial3 set Create 0 select File Save and close the file...

Страница 77: ...y sensor information Therefore Discover will not display any errors if a sensor is not connected to COM2 or COM3 If steps 3 through 6 were not carried out then these errors would be reported in the Di...

Страница 78: ...10 Check COM1 and set the correct baud rate for that device using the dropdown menu shown with a blue arrow in FIGURE 8 16 When the correct baud rate is set the State should say OK and Errors should...

Страница 79: ...BATHYMETRIC AND SIDE SCAN SONAR 0020300_REV_E Figure 8 16 Checking Serial Port Information 11 Click File Show Status in the sonar window as shown circled in red in FIGURE 8 17 Figure 8 17 Checking Sen...

Страница 80: ...marked by a purple box a If it is not increase the baud rate of the sensor Change the baud rate under Serial Port Information as shown in step 10 Check the Status again Otherwise the sonar will repor...

Страница 81: ...s for the two sensors 1 Follow steps 1 through 6 as stated previously under appendix sub section ONE SENSOR 2 Under Serial3 set Create 0 select File Save and close the file as shown in FIGURE 8 19 CAU...

Страница 82: ...green The correct data string should also be scrolling in the lower part of the window as shown in FIGURE 8 16 green arrow 7 Now Check COM2 and set the correct baud rate for the other device as done b...

Страница 83: ...the link capacity to stay open It is always wise to close the Remote Desktop when finished with the configurations 8 3 3 Three Sensors Three sensors such as a gyro heading a GPS position and time sou...

Страница 84: ...r Firmware by double clicking on the Sonar icon in the main Sonar Remote Desktop Screen as shown in FIGURE 8 15 designated by the green arrow 5 Now plug in the devices into COM 1 COM 2 and COM 3 The G...

Страница 85: ...e button and then on the dropdown menu named Config Item as shown by the green arrow in FIGURE 8 18 11 Select Serial green arrow then click on the Update button several times blue arrow in FIGURE 8 18...

Страница 86: ...8 69 Figure 8 22 Checking all COM Ports...

Страница 87: ...nnections The 6205s is compatible with data sent over the Ethernet connection via UDP The SonarSerial ini is utilized to configure the system to accept these messages Note that 1PPS functionality must...

Страница 88: ...anix POSVIEW software 1 Set the ethernet real time output data to groups 3 7 10 and 102 The output rate of the POSMV data should be set to 50Hz 2 The POSMV must also be set to Falling Negative Edge or...

Страница 89: ...not connected to COM1 COM2 or COM3 To configure the time synchronization sources 1 Locate and open the SonarConfig ini file This file is located in the same directory as the SonarSerial ini file that...

Страница 90: ...ext document CAUTION Do not alter the file in any way other than what has been specified This configuration sets the software to utilize the time and date reference received from the POSMV data string...

Страница 91: ...Configuration The 6205s is compatible with the Ekinox Apogee systems from SBG Systems Follow the below steps to configure the 6205s and the SBG for communication over the Ethernet interface via UDP R...

Страница 92: ...8 75 Figure 8 28 UDP broadcast settings example Figure 8 29 Eth1 data output...

Страница 93: ...8 76 6205s BATHYMETRIC AND SIDE SCAN SONAR 0020300_REV_E Figure 8 30 Data packets required but at 25Hz or 50Hz not 1Hz...

Страница 94: ...8 77 Figure 8 31 1PPS settings example Falling Edge and 1msec duration...

Страница 95: ...up down arrow keys select EUFI Corsair Voyager 3 0 000A then press Enter 5 Wait for Paragon Backup Recovery 14 Home screen to appear then click Restore icon 6 On Welcome to the Restore Wizard screen c...

Страница 96: ...Party topsides contact EDGETECH CUSTOMER SERVICE A 2 1 HYPACK The processed bathymetry and side scan data are sent in real time to the HYPACK HYSWEEP survey applications These applications display and...

Страница 97: ...n July 2014 supports EdgeTech s bathymetry and side scan data formats For more information on CARIS visit http www caris com A 2 5 EIVA NaviSuite EIVA s NaviSuite constitutes a complete advanced multi...

Отзывы: