Versatrax 150™
Document: UMDW014058.docm
Revision: A03
Created by: KW
Date: 10 Oct 2019
3075415-A03
Source Location: C:\ePDM\ISLEng\products\dw-versatrax150mkii\manuals\UMDW014058.docm
Page 33 of 57
User Ma
nual
Rear Camera Installation
The Versatrax 150
™ system comes standard with a rear facing Inuktun Sapphire™ camera. A bulkhead
connector, mounting collar and dummy plug is included with the harness block at the back of the vehicle.
WARNING:
High Voltage.
The bulkhead connector is supplied 36-70 VDC. This
connector must be plugged with a protective cap whenever the Sapphire camera
is removed. Fatal shock or system damage may otherwise result. Never operate
the system with this connector open.
Note:
The Sapphire camera uses a higher voltage and different pin-out than the Inuktun
Amber™
camera which is used on other Eddyfi Technologies equipment. You cannot use the Amber
with the Versatrax system. Attempts to install the Amber camera will damage the connector
and burn out the camera.
To install the Sapphire camera if not installed, do the following as shown below:
1. Remove the dummy plug from the rear bulk head connector.
2. Attach the mounting flange to the back of the Sapphire camera using 2x M3 x 16 mm FHMS.
3.
Plug the camera into the bulkhead connector
–
make sure to align the mating pins and grease the
male connector.
4. Screw down the mounting plate using M3 x 8 mm SHCS.
Removal is the reverse of installation
– make sure to cap bulkhead connector with a dummy plug.