E93.1803.901 HW
38
Diameters D
( = Connection between water heaters and tanks))
CB 85 HW
number of cascaded water heaters
ΔT = 16.5 °C
number of cascaded water heaters
ΔT = 12.5 °C
1
2
3
1
2
3
1 tank
42 x 1.5
54 x 1.5
64 x 2.0
42 x 1.5
54 x 1.5
-
2 tanks
42 x 1.5
54 x 1.5
64 x 2.0
42 x 1.5
54 x 1.5
76 x 2.0
CB 105 HW
number of cascaded water heaters
ΔT = 16.5 °C
number of cascaded water heaters
ΔT = 12.5 °C
1
2
3
1
2
3
1 tank
42 x 1.5
54 x 1.5
-
54 x 1.5
64 x 2.0
-
2 tanks
42 x 1.5
54 x 1.5
64 x 2.0
54 x 1.5
64 x 2.0
76 x 2.0
CB 125 HW
number of cascaded water heaters
ΔT = 16.5 °C
number of cascaded water heaters
ΔT = 12.5 °C
1
2
3
1
2
3
1 tank
42 x 1.5
64 x 2.0
-
54 x 1.5
76 x 2.0
-
2 tanks
42 x 1.5
64 x 2.0
76 x 2.0
54 x 1.5
76 x 2.0
88.9 x 2.0
CB 155 HW
number of cascaded water heaters
ΔT = 16.5 °C
number of cascaded water heaters
ΔT = 12.5 °C
1
2
3
1
2
3
1 tank
54 x 1.5
-
-
54 x 1.5
-
-
2 tanks
54 x 1.5
64 x 2.0
76 x 2.0
54 x 1.5
76 x 2.0
88.9 x 2.0
The final step is selecting the pump for each boiler. In table D below, a pump selection is made for every config-
uration from tables A, B and C. When applying this pump, the maximum allowable distance between water heaters
and tanks is expressed as V
L
. The definition of V
L
is shown in fig.1. From this distance, extra resistance in the
connecting pipes must be subtracted. These resistances are expressed as equivalent lengths and can be found
in table E
Pump codes and maximum distance V
L
CB 85 HW
number of cascaded water heaters
ΔT = 16.5 °C
number of cascaded water heaters
ΔT = 12.5 °C
1
2
3
1
2
3
1 tank
X
*
1: 2 x 9 m
2: 2 x 30 m
X
*
-
-
2 tanks
1: 2 x 30 m
1: 2 x 25 m 1: 2 x 12 m 2: 2 x 13 m
2: 2 x 9 m
-
CB 105 HW
number of cascaded water heaters
ΔT = 16.5 °C
number of cascaded water heaters
ΔT = 12.5 °C
1
2
3
1
2
3
1 tank
X
*
2: 2 x 30 m
-
X
*
-
-
2 tanks
1: 2 x 13 m
1: 2 x 10 m 2: 2 x 30 m 2: 2 x 25 m
2: 2 x 9 m
-
CB 125 HW
number of cascaded water heaters
ΔT = 16.5 °C
number of cascaded water heaters
ΔT = 12.5 °C
1
2
3
1
2
3
1 tank
X
*
2: 2 x 15 m
-
X
*
-
-
2 tanks
2: 2 x 28 m
2: 2 x 25 m 2: 2 x 30 m
-
-
-
CB 155 HW
number of cascaded water heaters
ΔT = 16.5 °C
number of cascaded water heaters
ΔT = 12.5 °C
1
2
3
1
2
3
1 tank
X
*
-
-
X
*
-
-
2 tanks
2: 2 x 30 m
2: 2 x 18 m
2: 2 x 7 m
-
-
-
Table
D: Pump advice and corresponding maximum length V
L.
X
*
: single boiler and tank, see paragraph 8.1.1 for pipe lengths
- : A - in the
table doesn’t necessarily mean that the corresponding installation cannot be built. If it can, it will need
specific design effort and pump selection. Please consult your supplier for advice.
Содержание CB 105 HW
Страница 69: ...E93 1803 901 HW 70 12 6 Electrical schematic...
Страница 70: ...E93 1803 901 HW 71...
Страница 71: ...E93 1803 901 HW 72 12 7 Ladder Logic Diagram LOW MAINS VOLTAGE VOLTAGE...
Страница 127: ...E93 1803 901 HW 128 22 SPARE PARTS CB 85 HW CB 105 HW and CB 125 HW exploded view...
Страница 128: ...E93 1803 901 HW 129...
Страница 129: ...E93 1803 901 HW 130 CB 155 HW exploded view...
Страница 130: ...E93 1803 901 HW 131...
Страница 145: ......
Страница 146: ......