Menu structure UA 300 D
Controller type UA 111 XP
66
Version 2.03 27. Juni 2008
7.2.1
Menu 0 Main menu
REFR. PT.
POS: XXXXX
1 Actual Values
Continue to Screen 1
2 Setpoints
Continue to Screen 2
3 Clock
Continue to Screen 3
4 Messages
Continue to Screen 4
5 Archive
Continue to Screen 5
6 Configuration
Continue to Screen 6
7.2.2
Menu 1 Actual Values
Actual Values
POS: XXXXX
1 Temp. Sensor
Continue to Screen 1−1
2 Cooling Zone 1
Continue to Screen 1−2
3 Defrost Zone 1
Continue to Screen 1−3
4
Not used with this controller type
5 Alarm
Continue to Screen 1−5
6 Compressor
Continue to Screen 1−6
7 Cooling Zone 2
Continue to Screen 1−7: Menu item is shown only when two−zone operation is set (Screen
6−1).
8 Defrost Zone 2
Continue to Screen 1−8: Menu item is shown only when two−zone operation is set (Screen
6−1).
S
Screen 1−1 Temp. Sensor
TEMPERATUR
POS: XXXXX
Temp. R2.1
XXX °C
Current supply air temperature Input Z11/Z12
Temp. R4.1
XXX °C
Current return air temperature Input Z21/Z22
Temp. R2.2
XXX °C
Current supply air temperature Input Z31/Z32
Temp. R2.3
XXX °C
Current supply air temperature Input Z41/Z42
Temp. R2.4
XXX °C
Current supply air temperature Input Z51/Z52
Temp. R2.5
XXX °C
Current supply air temperature Input Z61/Z62
Temp. R2.6
XXX °C
Current supply air temperature Input Z71/Z72
Temp. R2.7
XXX °C
Current supply air temperature Input Z81/Z82
Temp. R2.8
XXX °C
Current supply air temperature Input Z91/Z92
Temp. R4.8
XXX °C
Current return air temperature Input Z01/Z02
Содержание UA 300 D
Страница 2: ......
Страница 6: ...Table of contents iv Version 2 03 27 Juni 2008 Notice ...
Страница 8: ...System Design of UA 300 D 2 Version 2 03 27 Juni 2008 Notice ...
Страница 40: ...Installation and Startup of UA 300 D 34 Version 2 03 27 Juni 2008 Notice ...
Страница 54: ...Operation of UA 300 D 48 Version 2 03 27 Juni 2008 Notice ...
Страница 100: ...Menu structure UA 300 D Controller type UR 141 94 Version 2 03 27 Juni 2008 Notice ...
Страница 108: ...Specifications of UA 300 D 102 Version 2 03 27 Juni 2008 Notice ...