47
XSTORAGE HOME 3P INSTALLATION MANUAL
MN700009EN August 2020 www.eaton.com
00
Title
The xStorage Home 3P inverter provides one isolated change-over relay contact (4 A – 250 Vac max) which
allows activating secondary storage systems and / or domestic loads based on the state and energy balance
of the system.
WARNING:
To set the correct operation of the system with paralleled xStorage Home 3P units it is
necessary to access the “SETTINGS” configuration menu in INSTALLER mode and set the “SYSTEM”
parameters of the “IND. CAN” according to the characteristics of the system layout. Please refer to the
xStorage Home 3P user interface display manual. Moreover, INSTALLER mode is reserved only for Eaton
certified installers.
WARNING:
The system configuration with several xStorage Home 3P units in parallel is
possible up to a
maximum of 10 units.
WARNING:
The system configuration with several xStorage Home 3P units in parallel can only be carried
out by the AC GRID port.
The configuration of several units in parallel carried out by EPS port is
not permitted.
Any parallel connection of multiple units carried out by the EPS port can affect the correct
functioning of the system and relieves the manufacturer from all liabilities and invalidates the guarantee.
See the connection instructions shown in
Figure 18
.
WARNING: The relay contact can switch loads with absolute maximum ratings up to 4 A – 250 Vac.
If you intend to control loads with higher rated power, it is necessary to install an external switch and use
the xStorage Home 3P contact to create the control circuit of the external switch.
WARNING:
To set the contact operating mode it is necessary to access the “SETTINGS” configuration menu
and set the “LD1 - SMART LOAD” parameters of the “HOME AUTOMATION” menu according to the desired
energy management needs. Please refer to the xStorage Home 3P user interface display manual.
6.11 SMART LOAD Connection