1 Device series DC1-S…
1.6 Voltage categories
DC1-S…20…, DC1-S…OE1 Variable Frequency Drives
05/21 MN040058EN
www.eaton.com
19
1.6 Voltage categories
DC1-S… variable frequency drives are divided into two voltage categories:
•
115 V: 110 - 115 V ±10 %
→
DC1-
S1
…
•
200 V: 200 - 240 V ±10 %
→
DC1-
S2
…
DC1-
S1
…
•
Single-phase mains connection, rated operating voltage 115 V
•
U
LN
= 1~, 110 - 115 V ±10 %, 50/60 Hz
•
I
e
= 7 - 11 A
•
Motor: 0.37 - 0.55 kW (115 V, 50 Hz), 1/2 - 3/4 HP (115 V, 60 Hz)
DC1-
S2
…
•
Single-phase mains connection, rated operating voltage 230 V
•
U
LN
= 1~, 200 - 240 V ±10 %, 50/60 Hz
•
I
e
= 4.3 - 11 A
•
Motor: 0.37 - 1.1 kW (230 V, 50 Hz), 1/2 - 1.5 HP (230 V, 60 Hz)
Figure 8:
DC1-S1… / DC1-S2…
Mains, U
LN
= 1 ~ 110 - 115 V ±10 %
U
LN
= 1 ~ 200 - 240 V ±10 %
115 V (U
LN
= 115 V)
230 V (U
LN
= 230 V)
L
N
PE
U
V
U1
V1
EMC Filter
L1/L
L2/N
BR
DC+
M
1∼
Motor
I
e
Brake chopper
(DC1-S…
B
-A20…)
FS2