7 Technical Data
7.2 Specific rated operational data
162
DC1-S…20…, DC1-S…OE1 Variable Frequency Drives
05/21 MN040058EN
www.eaton.com
7.2.1 DC1-S1… device series
Size
Symbol
Unit
7D0
011
Rated operational current
I
e
A
7.0
10.5
Overload current for 60 s every 600 s
i
l
A
10.5
16.5
Assigned motor output
P
kW
0.37
0.55
P
HP
0.5
0.75
Power side (primary side):
Number of phases
single-
phase
single-
phase
Rated operating voltage
U
LN
V
110 (-10 %) - 115 (+10 %)
48 - 62 Hz
99 - 126 ±0 %
Input current (phase current)
I
LN
A
8.5
12.5
Switching frequency (pulse frequency)
Default Setting
f
PWM
kHz
8
8
Setting range
f
PWM
kHz
4 - 32
4 - 32
Maximum leakage current to earth (touch
current), at U
LN
: 120 V, without motor
I
Touch
mA
4.8
4.8
Efficiency
η
0.95
0.95
Heat dissipation
At I
e
(150 %)
P
V
W
63
103.4
During no-load running, standby
(locked, without fan)
P
V
W
3.07
3.07
Fan, built-in
–
✓
1)
Construction size
FS1
FS1
1) Not with IP66 degree of protection
Содержание PowerXL
Страница 4: ......
Страница 124: ...5 Operation 5 7 Handling the keypad 120 DC1 S 20 DC1 S OE1 Variable Frequency Drives 05 21 MN040058EN www eaton com...
Страница 160: ...6 Parameter structure 6 7 Fault messages 156 DC1 S 20 DC1 S OE1 Variable Frequency Drives 05 21 MN040058EN www eaton com...
Страница 170: ...7 Technical Data 7 3 Dimensions 166 DC1 S 20 DC1 S OE1 Variable Frequency Drives 05 21 MN040058EN www eaton com...