3 Installation
3.6 Electrical Installation
68
DC1-S…20…, DC1-S…OE1 Variable Frequency Drives
05/21 MN040058EN
www.eaton.com
Table 7:
Terminals (IP66)
Size
Connection terminals
Description
FS1
Connection with single-phase supply voltage:
• DC1-S1… (115 V)
• DC1-S2… (230 V)
Hint:
Connection to terminal L3 not permissible!
Motor connection for single-phase AC motor:
• DC1-S1… (115 V)
• DC1-S2… (230 V)
FS2
Connection with single-phase supply voltage:
• DC1-S1… (115 V)
• DC1-S2… (230 V)
Hint:
Connection to terminal L3 not permissible!
Motor connection for single-phase AC motors:
• DC1-S1… (115 V)
• DC1-S2… (230 V)
Hint:
+
,
BR
: Connection for external brake resistors
(
BR
= Output Brake Chopper).
The terminals’ plastic cover can be removed if necessary.
Terminal
+
has the same function as terminal
DC+
in devices with an
IP20 degree of protection.
L1/L
L2/N
L3
⏚
L
N
PE
U
V
W
⏚
PES
M
DC-
L1/L
L2/N
L3
⏚
L
N
PE
PES
DC+
BR
U
V
W
⏚
R
B
M
Содержание PowerXL
Страница 4: ......
Страница 124: ...5 Operation 5 7 Handling the keypad 120 DC1 S 20 DC1 S OE1 Variable Frequency Drives 05 21 MN040058EN www eaton com...
Страница 160: ...6 Parameter structure 6 7 Fault messages 156 DC1 S 20 DC1 S OE1 Variable Frequency Drives 05 21 MN040058EN www eaton com...
Страница 170: ...7 Technical Data 7 3 Dimensions 166 DC1 S 20 DC1 S OE1 Variable Frequency Drives 05 21 MN040058EN www eaton com...