Display Menu Operation
Table 7-3 describes the menu functions and how to use them.
Table 7-3. Display Menu Operation
Function
Subfunction
Operation
Events
Press the
EVENTS
pushbutton on the main menu bar or History menu bar to display a listing of all
system events that are currently active. The most recent event is listed first. As events clear, they are
removed from the Active System Events listing. To scroll through the events, press the up or down
arrow pushbutton on the menu bar.
User History
Press the
HISTORY
pushbutton on the Active Events menu bar to display the User History Log. The
User History Log lists up to 2048 events in chronological order, with the most recent event listed last
(once 2048 is reached, the earliest event is overwritten). The end of the log (the most recent events) is
displayed first; scroll upward to view older event listings. To scroll through the events, press the up or
down arrow pushbutton on the menu bar. To return to the Active Events screen, press the
EVENTS
pushbutton on the menu bar.
Service History
The Service History Log is for service personnel and is password protected. If the customer needs
access to the log, contact an Eaton service representative.
Press the
SERVICE
pushbutton on the User History menu bar to display the Service History Log. The
Service History Log lists up to 2048 events in chronological order, with the most recent event listed
last (once 2048 is reached, the earliest event is overwritten). The end of the log (the most recent
events) is displayed first; scroll upward to view older event listings. To scroll through the events,
press the up or down arrow pushbutton on the menu bar. To return to the User History screen, press
the
USER
pushbutton on the menu bar. To return to the Active Events screen, press the
EVENTS
pushbutton on the menu bar.
Meters
UPS
Meters
UPM
The Meter screens show the UPS meter readings for the unit. The default voltage displayed on these
screens is phase-to-neutral. However, an authorized Eaton Customer Service Engineer can change the
screens to display the voltage phase-to-phase (A-B, B-C, C-A). Press the
METERS
pushbutton on the
main menu bar to display the Meter screens. To scroll through the meter screens, press the up or
down arrow pushbutton on the menu bar. The current UPS readings are displayed in the information
area of the screen.
Output
UPS
Output
UPM
The Output screen shows output voltage (phase
to
neutral), output current (each phase), and
frequency being supplied by the UPS, as well as the kVA, kW, and power factor measurements.
Input
UPS
Input
UPM
The Input screen shows input voltage (phase
to
neutral), input current (each phase), and frequency of
the incoming utility source, as well as the kVA, kW, and power factor measurements.
Bypass
The Bypass screen shows the bypass input voltage (phase
to
neutral), input current (each phase), and
frequency of the incoming utility source, as well as the kVA, kW, and power factor measurements.
Battery
UPS
Battery
UPM
The Battery screen displays the battery voltage (Vdc), the battery current (Idc), the minutes of battery
time remaining, and battery temperature. Battery temperature must be set up by an authorized Eaton
Customer Service Engineer. When battery life decreases to less than 20%, Check Battery is displayed.
Statistics
The Statistics screen displays the hours on line and the total kW hours used.
Output Current
UPS
Output Current
UPM
The Output Current screen displays a real
time bar graph of the output current of the UPS. The graph
shows the current for each phase.
Output Power
UPM
The Output Power screen displays the power in kW and kVA for each UPM.
System Level 0 Setup
Function Selection
This screen can be used to set the screen contrast, show the firmware versions installed, identify the
unit type, change the display language, set up Energy Saver functions, set up Advanced Power
Management functions, and enter a password to access Level 1 functions. Press the
SETUP
pushbutton on the main menu bar to display the System Setup Level 0 Screen. No password is
necessary to access Level 0 functions. Use the up or down arrow pushbutton to highlight the setup
function screen desired, then press the
SELECT
pushbutton to display the function screen.
Contrast Adjust
Select
CONTRAST
from the System Setup Level 0 menu to display the Contrast Adjust screen. Use
the left or right arrow pushbutton to adjust the contrast for the LCD. When the contrast adjustment is
complete, press the
SAVE
pushbutton
.
Once the setting is saved, the System Setup screen displays.
To return to the System Setup screen without saving the setting, press the