4 Commissioning
4.5 Acyclic data
DX-NET-SWD...
08/14 MN04012009Z-EN
www.eaton.com
69
2130
0
P3-11
-
–
RUN
rw
U16
PID1 fault ramp
PID deviation from ramp
activation
2131
0
P3-13
P-49
–
RUN
rw
U16
PID1 FeedbackWakeUp
Actual value wakeup level
for controller
900
≙
90.0 %
2132
0
P3-18
–
–
RUN
rw
U16
PID1 ResetControl
PID reset control
2150
0
P0-08
–
–
STOP
ro
PID1 setpoint
PID setpoint value
2151
0
P0-09
–
–
STOP
ro
PID feedback 1
2152
0
P0-10
–
–
-
ro
PID 1 OUT
2200
0
P6-19
–
–
RUN
rw
U16
Braking resistance
Braking resistance
2201
0
P6-20
–
–
RUN
rw
U16
P braking resistance
Braking resistance output
2202
0
P6-21
–
–
RUN
rw
U16
Braking chopper
DutyCycle
Braking chopper cycle in the
event of excessively low
temperature
2203
0
P6-17
–
–
RUN
rw
U16
Max torque timeout
Time at maximum torque
after which a fault message
will be sent
2204
0
–
P-34
–
RUN
rw
U16
Brake chopper
Brake chopper activation
For more information, please
refer to the manual for the
basic device.
2220
0
P6-18
–
P-27
RUN
rw
U16
DCBrakingVoltage
Used to define the DC
voltage, as a percentage of
the motor's rated voltage,
that will be applied to the
motor during DC braking.
2221
0
–
P-32
P-25
RUN
rw
U16
DCBraking
Used to define the operating
states in which DC braking
will be activated.
2223
0
–
–
P-28
RUN
rw
f-DC-Braking@Stop
Percentage of the maximum
frequency at which DC
braking will start during the
deceleration phase.
2230
0
P6-11
–
P-26
RUN
rw
U16
SpeedHold release time
DC braking duration
2230
1
P6-12
–
–
RUN
rw
U16
SpeedHold inhibit time
Speed holding time in the
event of inhibit
2250
0
P6-13
–
–
RUN
rw
U16
Brake release delay
Motor brake release time
1
P6-14
–
–
RUN
rw
U16
Brake Apply delay
Motor brake engagement
delay
2251
0
P6-15
–
–
RUN
rw
U16
Brake release M level
Minimum torque for
releasing the brake
2252
0
P6-16
–
–
RUN
rw
U16
Brake timeout M level
Minimum torque –timeout
2300
0
P6-06
–
–
RUN
rw
U16
Encoder PPR
Encoder pulses per
revolution
2301
0
P6-05
–
–
RUN
rw
WORD
Encoder actual value
enable
Enable for encoder feedback
PNU
Index
PNU
Subindex
Parameter number in
specific device
Access right
Data type
Name
Description
DA1
DC1
DE1
RUN/
STOP
ro/rw
Содержание Power XL SmartWire-DT DX-NET-SWD Series
Страница 4: ...II ...
Страница 10: ...0 About this Manual 0 7 Units of measurement 6 DX NET SWD 08 14 MN04012009Z EN www eaton com ...
Страница 32: ...3 Installation 3 3 Install SmartWire DT connection 28 DX NET SWD 08 14 MN04012009Z EN www eaton com ...
Страница 92: ...4 Commissioning 4 6 SmartWire DT diagnostics 88 DX NET SWD 08 14 MN04012009Z EN www eaton com ...