4 Wiring with
4.15 Circuit examples
Operating instructions
05/10 MN05013003Z-EN
www.eaton.com
161
Figure 89:
Stairwell lighting with easy
Button pressed briefly
Light ON or OFF. The impulse relay function will even switch off Continuous lighting.
Light off after 6 min. with Continuous lighting this function is not active.
Button pressed for more
than 5 s
continuous light
N
L
S1
S2
S3
E1
E2
E3
1
2
Q1
I1
L N