Voltage Relay 

RN-16D

Summary of Contents for RN-16D

Page 1: ...USER S MANUAL www sven fi Voltage Relay RN 16D ...

Page 2: ...N Despite the exerted efforts to make this Manual more exact some discre pancies may occur The information in this Manual is given on as is terms The author and the publisher do not bear any liability to a person or an or ganization for loss or damage which has arisen from the information con tained in this Manual CONTENTS ENG 1 PRECAUTIONS 2 PACKAGE CONTENTS 3 APPLICATION 4 FEATURES 5 TECHNICAL DE...

Page 3: ...anic compounds alcohol petrol solvents etc to clean the device It is prohibited to open and repair the device on your own It is prohibited to open and repair any protected equipment if it is con nected to the device socket It is prohibited to use the device with mechanical damages of its case It is prohibited to use the device in high humidity conditions Avoid ingress of water into the device Ship...

Page 4: ...status indication Protective shutters in the output socket Presence of protective fuse 15А 5 TECHNICAL DESCRIPTION RN 16D voltage relay presents a device with an electronic circuit with microprocessor control assembled in a case with a wall plug and socket RN 16D voltage relay provides the power supply disconnection of appliances connected to it if the power supply voltage exceeds specified values ...

Page 5: ...n to enter the programming mode and select programmable parameters c UP button to increase the value of a parameter being set d DOWN button to decrease the value of a parameter being set e ON forced load button exit button from the parameter setting mode f Protective shutters g Grounding contacts h Wall plug to connect the voltage relay to 230 V 50 Hz power supply network socket Fig 1 ENG User s M...

Page 6: ...ust be in the range 10 to 35 С Before connecting equipment to the voltage relay it is necessary to set actuation values namely high voltage switching off threshold UH low voltage switching off threshold UL and turn on delay time after voltage normalization of the power supply network td see p 7 It is recom mended to set these values in accordance with operation manuals of connected equipment The tur...

Page 7: ...symbol and the upper switching off threshold value UL in volts on the display a Set a required value using buttons UP c and DOWN d The range of possible values of the UL parameter is 150 to 215 V Start setting turn on delay value by pressing the button SET b There will be the flashing SET DS symbol and delay value td in seconds on the display Set a required value using buttons UP c and DOWN d The ra...

Page 8: ...he actual value of the mains voltage and symbols LV HV voltage below above the set limit The sub illumination of the LCD indicator in this mode is jerky The voltage relay will be in this mode as long as the voltage in the power supply network returns to the range of values from UL 7 V to UH 7 V The relay enters the turn on delay mode after its connection to the network or when it leaves the protec...

Page 9: ...ply voltage V delay time sec Default value factory setting Dimensions mm Value 140 280 50 15 3 3 125 operating mode 2500 protective mode 4500 not more than 0 3 seconds 140 280 2 150 215 1 V step 225 275 1 V step 5 999 1 sec step Ulow 198 В Uhi 253 В Delay 5 sec 72 86 39 max 78 Notes The data on the varistor fuse shown in the table are background and can not serve as a basis for claims Technical sp...