8 Appendix
8.3 Technical data
Operating instructions
05/10 MN05013003Z-EN
www.eaton.com
221
Inductive load (without external suppressor circuit)
General explanations:
T
0.95
= time in milliseconds until 95 % of the stationary current is reached.
Utilization category in groups for:
•
Q1 to Q4,
•
Q5 to Q8,
•
S1 to S4,
•
S5 to S8.
Number of outputs
≦
4
≦
4
total maximum current
2.0 A, Caution! Outputs must be actuated simultaneously and for the same time
duration.
Status indication of the
outputs
LCD display (if provided)
T
0.95
≈
3 x T
0.65
= 3 x
L
R
T
0.95
= 1 ms
R = 48
Ω
L = 16 mH
Utilization factor
g = 0.25
Relative duty factor
%
100
Maximum switching frequency f = 0.5
Hz
Maximum duty factor DF = 50 %
Operations/h
1500
DC13
T
0.95
= 72 ms
R = 48
Ω
L = 1.15 H
Utilization factor
g = 0.25
Relative duty factor
%
100
Maximum switching frequency f = 0.5
Hz
Maximum duty factor DF = 50 %
Operations/h
1500
Other inductive loads:
T
0.95
= 15 ms
R = 48
Ω
L = 0.24 H
Utilization factor
g = 0.25
Relative duty factor
%
100
Maximum switching frequency f = 0.5
Hz
Maximum duty factor DF = 50 %
Operations/h
1500
Inductive load with external suppressor circuit for each load (see section “Connecting transistor outputs” on )
Utilization factor
g = 1
Relative duty factor
%
100
max. operating frequency
Max. duty factor
Operations/h
Depending on the
suppressor circuit
EASY512-D.-T…
EASY620-DC-.E, EASY72…
Содержание easy500, easy700
Страница 1: ...Operating Instructions Control Relay 500 700 05 10 MN05013003Z EN replaces 05 04 AWB2528 1508GB...
Страница 4: ...II...
Страница 28: ...1 1 5 operating principles 24 Operating instructions 05 10 MN05013003Z EN www eaton com...
Страница 54: ...2 Installation 2 8 Connecting bus systems 50 Operating instructions 05 10 MN05013003Z EN www eaton com...
Страница 190: ...5 settings 5 10 Displaying device information 186 Operating instructions 05 10 MN05013003Z EN www eaton com...
Страница 210: ...7 What Happens If 7 3 Event 206 Operating instructions 05 10 MN05013003Z EN www eaton com...
Страница 234: ...9 Glossary of terms 230 Operating instructions 05 10 MN05013003Z EN www eaton com...